Direct Measurement of Longitudinal Strains and Stresses within Single Lap Shear Adhesive Joints Using Neutron Diffraction
Authors:
- 1 May 1999
- journal article
- research article
- Published by Taylor & Francis in The Journal of Adhesion
- Vol. 70 (1-2) , 1-11
Abstract
The neutron diffraction technique has been used to investigate the longitudinal stresses in the adherend produced as a result of cure and due to the application of a tensile load in a single lap shear joint. A comparison has also been made between the stress distributions in loaded “aged” and “unaged” joints. The neutron diffraction technique is the only viable method of investigating these stresses within metal adherends and enables comparisons between predicted and measured stresses to be made. The results of these experiments cast doubt on some of the predictions from finite element modelling of adherend stress levels.Keywords
This publication has 6 references indexed in Scilit:
- Three-dimensional deformations in a single-lap jointThe Journal of Strain Analysis for Engineering Design, 1994
- The effect of temperature on the strength of adhesive jointsInternational Journal of Adhesion and Adhesives, 1992
- Measurement of Residual and Applied Stress Using Neutron Diffraction1992
- Residual stresses in chains: Comparison of neutron diffraction and finite element resultsMaterials Science and Technology, 1990
- Influence of the Spew Fillet and other Parameters on the Stress Distribution in the Single Lap JointThe Journal of Adhesion, 1981
- Stress analysis of adhesive-bonded lap jointsJournal of Strain Analysis, 1974