Validity of Cardiorespiratory Fitness Measured with Fitbit Compared to V˙O2max
Authors:
Open Access
- 21 May 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 51 (11) , 2251-2256
Abstract
Purpose: Cardiorespiratory fitness (CRF), broadly defined as the body’s ability to utilize oxygen, is a well-established prognostic marker of health, but it is not routinely measured. This may be due to the difficulty of acquiring high-quality CRF measures. The purpose of this study was to independently determine the validity of the Fitbit Charge 2’s measure of CRF (Fitbit CRF). Methods: Sixty-five healthy adults between the ages of 18 and 45 yr (55% female, 45% male) were recruited to undergo gold standard V˙O2max testing and wear a Fitbit Charge 2 continuously for 1 wk during which they were instructed to complete a qualifying outdoor run to derive the Fitbit CRF (units: mL·kg−1·min−1). This measure was compared with V˙O2max measures (units: mL·kg−1·min−1) epoched at 15 and 60 s. Results: Bland–Altman analyses revealed that Fitbit CRF had a positive bias of 1.59 mL·kg−1·min−1 compared with laboratory data epoched at 15 s and 0.30 mL·kg−1·min−1 compared with data epoched at 60 s (n = 60). F statistics (2.09; 0.08) and P values (0.133; 0.926) from Bradley–Blackwood tests for the concordance of Fitbit CRF with 15- and 60-s laboratory data, respectively, support the null hypothesis of equal means and variances, indicating there is concordance between the two measures. Mean absolute percentage error was less than 10% for each comparison. Conclusions: The Fitbit Charge 2 provides an acceptable level of validity when measuring CRF in young, healthy, and fit adults who are able to run. Further research is required to determine if it is a potentially useful tool in clinical practice and epidemiological research to quantify, categorize, and longitudinally track risk for adverse outcomes.Keywords
This publication has 25 references indexed in Scilit:
- Exercise Standards for Testing and TrainingCirculation, 2013
- Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010The Lancet, 2012
- Smart wearable systems: Current status and future challengesArtificial Intelligence in Medicine, 2012
- A non-exercise testing method for estimating cardiorespiratory fitness: associations with all-cause and cardiovascular mortality in a pooled analysis of eight population-based cohortsEuropean Heart Journal, 2012
- Cardiorespiratory Fitness and Classification of Risk of Cardiovascular Disease MortalityCirculation, 2011
- Clinician’s Guide to Cardiopulmonary Exercise Testing in AdultsCirculation, 2010
- Alterations in VO2max and the VO2 plateau with manipulation of sampling intervalClinical Physiology and Functional Imaging, 2008
- The predictive value of cardiorespiratory fitness combined with coronary risk evaluation and the risk of cardiovascular and all‐cause deathJournal of Internal Medicine, 2007
- Physical fitness and all-cause mortality. A prospective study of healthy men and womenJAMA, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986