Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction
Open Access
- 8 October 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (21) , R297-R322
Abstract
MRI is often the most sensitive or appropriate technique for important measurements in clinical diagnosis and research, but lengthy acquisition times limit its use due to cost and considerations of patient comfort and compliance. Once an image field of view and resolution is chosen, the minimum scan acquisition time is normally fixed by the amount of raw data that must be acquired to meet the Nyquist criteria. Recently, there has been research interest in using the theory of compressed sensing (CS) in MR imaging to reduce scan acquisition times. The theory argues that if our target MR image is sparse, having signal information in only a small proportion of pixels (like an angiogram), or if the image can be mathematically transformed to be sparse then it is possible to use that sparsity to recover a high definition image from substantially less acquired data. This review starts by considering methods of k-space undersampling which have already been incorporated into routine clinical imaging (partial Fourier imaging and parallel imaging), and then explains the basis of using compressed sensing in MRI. The practical considerations of applying CS to MRI acquisitions are discussed, such as designing k-space undersampling schemes, optimizing adjustable parameters in reconstructions and exploiting the power of combined compressed sensing and parallel imaging (CS-PI). A selection of clinical applications that have used CS and CS-PI prospectively are considered. The review concludes by signposting other imaging acceleration techniques under present development before concluding with a consideration of the potential impact and obstacles to bringing compressed sensing into routine use in clinical MRI.Keywords
This publication has 73 references indexed in Scilit:
- Quantitative Muscle MRI as an Assessment Tool for Monitoring Disease Progression in LGMD2I: A Multicentre Longitudinal StudyPLOS ONE, 2013
- Evaluation of heterogeneous metabolic profile in an orthotopic human glioblastoma xenograft model using compressed sensing hyperpolarized 3D 13C magnetic resonance spectroscopic imagingMagnetic Resonance in Medicine, 2012
- Coil compression for accelerated imaging with Cartesian samplingMagnetic Resonance in Medicine, 2012
- Incorporation of prior knowledge in compressed sensing for faster acquisition of hyperpolarized gas imagesMagnetic Resonance in Medicine, 2012
- Fast $\ell_1$-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible RuntimeIEEE Transactions on Medical Imaging, 2012
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- Improved Pediatric MR Imaging with Compressed SensingRadiology, 2010
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Automatic coil selection for channel reduction in SENSE-based parallel imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986