Change in Hemorrheological and Biochemical Parameters following Membrane Differential Filtration
Authors:
- 1 December 1995
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 18 (12) , 794-798
Abstract
Introduction: The elimination of high molecular weight proteins may have a positive influence on disorders of the microcirculation due to an improvement in rheological parameters. We therefore attempted to evaluate the rheological efficacy of membrane differential filtration (MDF). Patients and methods: Ten patients suffering from macular disease underwent MDF. Rheological and biochemical parameters as well as visual acuity were determined one day before and after therapy: The study aimed at a reduction in plasma viscosity, standardized whole blood viscosity at hematocrit 0.45 and erythrocyte aggregation at hematocrit 0.3. Results: Severe side-effects were not observed. The rheological parameters were significantly reduced. In detail the posttreatment values were reduced as compared to the pretreatment values as follows: plasma viscosity 85%, standardised whole blood viscosity 86% (hematocrit 0.45), erythrocyte aggregation 59% (hematocrit 0.3), total protein 81%, IgG 66%, IgA 59%, IgM 33%, alpha-2-macroglobulin 30%, triglycerides 102%, total cholesterol 47%, VLDL cholesterol 94%, LDL cholesterol 33%, HDL cholesterol 62%. Visual acuity was improved in 7/10 patients. Conclusions: MDF is a safe and highly effective method for lowering biochemical and improving rheological parameters which led to improvement in visual acuity. We have already replaced plasma exchange with MDF in our clinical practice of hemorrheological therapy.Keywords
This publication has 16 references indexed in Scilit:
- Three-year treatment of familial heterozygous hypercholesterolemia by extracorporeal low-density lipoprotein immunoadsorption with polyclonal apolipoprotein B antibodiesMetabolism, 1993
- Haemorheological changes in patients with retinal vein occlusion after isovolaemic haemodilution.British Journal of Ophthalmology, 1990
- Blood flow in microvascular networks. Experiments and simulation.Circulation Research, 1990
- Akute Wirkungen der extrakorporalen LDL-Cholesterin- und Fibrinogen-Elimination auf Blutrheologie und Mikrozirkulation*DMW - Deutsche Medizinische Wochenschrift, 1990
- Kinetik der Lipide und Lipoproteine mit Bestimmung der Recovery-Rate im Non Steady State nach Plasma-, Membranfiltrations- und Dextransulfatadsorptionsapherese bei Hypercholesterinämie - Kinetics of Lipids and Lipoproteins with Determination of Recovery Rates in non-steady state after Plasma-, Membranefiltration and Dextransulfate Adsorption Apheresis for HypercholesterolemiaBiomedical Engineering / Biomedizinische Technik, 1989
- Alterations in the HDL system after rapid plasma cholesterol reduction by LDL-apheresisMetabolism, 1988
- MORTALITY IN THERAPEUTIC HAEMAPHERESISThe Lancet, 1983
- Das Mini-Erythrozyten-Aggregometer: Ein neues Gerät zur schnellen Quantifizierung des Ausmaßes der Erythrozyten-aggregation Mini Erythrocyte Aggregometer: A New Apparatus for Rapid Quantification of the extent of Erythrocyte AggregationBiomedical Engineering / Biomedizinische Technik, 1982
- Effects of lipoproteins on plasma viscosityAtherosclerosis, 1981
- Studies of plasma viscosity in primary hyperlipoproteinaemiaAtherosclerosis, 1977