Long-term Results of One-Level Lumbar Arthroplasty
Author:
- 1 March 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 32 (6) , 661-666
Abstract
A retrospective chart and radiographic review. To determine the long-term clinical results, radiographic results, and incidence of complications in a large patient cohort with one-level lumbar total disc replacement (TDR). Prior authors have described short-term, mid-term, and long-term clinical and radiographic results in patients with lumbar TDR with highly variable results. From January 1989 to November 1995, 108 patients, with a mean age of 36.4 years, underwent lumbar TDR with the CHARITE Artificial Disc, with 106 available for follow-up. A modified Stauffer-Coventry scale was used to determine clinical outcome. Return to work, work level, and the incidence of complications were assessed. Dynamic lateral flexion-extension and lateral bending radiographs were performed and segmental range of motion (ROM) was measured using the Cobb method. Mean follow-up time was 13.2 years (range, 10-16.8 years). Of the 106 patients, 87 (82.1%) had either an excellent or good clinical outcome. Of the 96 patients working before surgery, 86 returned to work (89.6%), including 77.8% of patients with hard labor level employment (28 of 36) returning to the same level of work. The mean ROM in flexion-extension was 10.1 degrees , in lateral bending it was 4.4 degrees , and 90.6% of implanted prostheses were still mobile. Eight patients (7.5%) required posterior instrumented fusion. There were 5 cases (4.6%) of postoperative facet arthrosis, 3 cases (2.8%) of subsidence, 3 cases (2.8%) of adjacent-level disease, and 2 cases (1.9%) of core subluxation. This retrospective study demonstrates the safety and efficacy of the CHARITE Artificial Disc at one level, either L4-L5 or L5-S1, in the long-term. Clinical outcomes and the rate of return to work were excellent overall. The rate of adjacent-level disease requiring surgical intervention was considerably lower (2.8%) compared with reports in the literature for lumbar fusion. As with any surgical procedure, proper indications play a pivotal role in clinical success.Keywords
This publication has 24 references indexed in Scilit:
- A Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemptions Study of Lumbar Total Disc Replacement With the CHARITÉ™ Artificial Disc Versus Lumbar FusionSpine, 2005
- Point of View: Commentary on the Research Reports that Led to Food and Drug Administration Approval of an Artificial DiscSpine, 2005
- Intra-arterial Thrombolysis for Acute Ischemic Stroke: Preliminary Experience with Platelet Glycoprotein IIb/IIIa Inhibitors as Adjunctive TherapyNeurosurgery, 2005
- Neurological complications of lumbar artificial disc replacement and comparison of clinical results with those related to lumbar arthrodesis in the literature: results of a multicenter, prospective, randomized investigational device exemption study of Charité intervertebral discJournal of Neurosurgery: Spine, 2004
- ADJACENT SEGMENT DEGENERATION IN THE LUMBAR SPINEJournal of Bone and Joint Surgery, 2004
- Biomechanical Evaluation of Total Disc Replacement Arthroplasty: An In Vitro Human Cadaveric ModelSpine, 2003
- The Fate of the Adjacent Motion Segments After Lumbar FusionJournal of Spinal Disorders & Techniques, 2003
- Total disc replacement for chronic low back pain: background and a systematic review of the literatureEuropean Spine Journal, 2003
- History, design and biomechanics of the LINK SB Charité artificial discEuropean Spine Journal, 2002
- Optimal minimally traumatic approach for the SB Charité™ Artificial DiscEuropean Spine Journal, 2002