Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite Electrode
- 3 April 2017
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 29 (6) , 1626-1634
Abstract
A Pt nanoparticle modified Pencil Graphite Electrode (PGE) was proposed for the electrocatalytic oxidation and non‐enzymatic determination of H2O2 in Flow Injection Analysis (FIA) system. Platinum nanoparticles (PtNPs) electrochemically deposited on pretreated PGE (p.PGE) surface by recording cyclic voltammograms of 1.0 mM of H2PtCl6 solution in 0.10 M KCl at scan rate of 50 mV s−1 for 30 cycles. Cyclic voltammograms show that the oxidation peak potential of H2O2 shifts from about +700 mV at bare PGE to +50 mV at PtNPs/p.PGE vs. Ag/AgCl /KCl (sat.). It can be concluded that PtNPs/p.PGE exhibits a good electrocatalytic activity towards oxidation of H2O2. Then, FI amperometric analysis of H2O2 was performed under optimized conditions using a new homemade electrochemical flow cell which was constructed for PGE. Linear range was found as 2.5 μM to 750.0 μM H2O2 with a detection limit of 0.73 μM (based on Sb/m of 3). As a result, this study shows the first study on the FI amperometric determination of H2O2 at PtNPs/p.PGE which exhibits a simple, low cost, commercially available, disposable sensor for H2O2 detection. The proposed electrode was successfully applied to determination of H2O2 in real sample.Keywords
Funding Information
- Scientific and Technological Research Council of Turkey
This publication has 53 references indexed in Scilit:
- Sensing Glucose in Urine and Serum and Hydrogen Peroxide in Living Cells by Use of a Novel Boronate Nanoprobe Based on Surface-Enhanced Raman SpectroscopyAnalytical Chemistry, 2016
- Branched Platinum Nanostructures on Reduced Graphene: An excellent Transducer for Nonenzymatic Sensing of Hydrogen Peroxide and Biosensing of XanthineElectrochimica Acta, 2016
- Multi-input and -output logic circuits based on bioelectrocatalysis with horseradish peroxidase and glucose oxidase immobilized in multi-responsive copolymer films on electrodesBiosensors and Bioelectronics, 2016
- Paper-based enzymatic reactors for batch injection analysis of glucose on 3D printed cell coupled with amperometric detectionSensors and Actuators B: Chemical, 2016
- A novel paper-based device coupled with a silver nanoparticle-modified boron-doped diamond electrode for cholesterol detectionAnalytica Chimica Acta, 2015
- Fluorescent blood glucose monitor by hemin-functionalized graphene quantum dots based sensing systemAnalytica Chimica Acta, 2014
- Photoelectrochemical glucose biosensor incorporating CdS nanoparticlesParticuology, 2009
- Ethanol biosensors based on alcohol oxidaseBiosensors and Bioelectronics, 2005
- Hydrogen Peroxide PoisoningToxicological Reviews, 2004
- Hydrogen peroxide in the human bodyFEBS Letters, 2000