Histomorphology of thrombus organization, neointima formation, and foreign body response in retrieved human aneurysms treated with hydrocoil devices
- 22 June 2010
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 94B (2) , 486-492
Abstract
Biological processes, such as thrombus organization, endothelialization, and foreign body response, that occur following embolization of intracranial aneurysms are poorly understood. We examined 13 human aneurysms (retrieved at autopsy 1–74 days postembolization) treated with hybrid hydrogel‐platinum coil devices and platinum coils. The specimens were embedded in methyl methacrylate and ground sections were surface stained. Using light microscopy, thrombus organization in the sac, endothelialization of the neck, and foreign body response to the embolic devices were determined. The area percentages of the sac occupied by embolic devices and unorganized thrombus were quantified using image analysis. Thrombus organization increased over time, but was incomplete up to 74 days post‐treatment. Neointima formation had started at 5 days upon dense fibrin depositions and progressed to form a new vessel wall at 74 days. The foreign body response to the hydrogel was characterized by mononuclear macrophages, while platinum coils were surrounded by multinuclear foreign body giant cells. Histometric aneurysm occlusion ranged from 89 to 100% and embolic devices occupied 31–64% of the aneurysm sac. These findings showed that the hydrogel‐based devices occupied a large percentage of the aneurysm sac, provided a framework for thrombus organization to occur, and elicited less severe foreign body response than platinum coils. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.Keywords
This publication has 25 references indexed in Scilit:
- Relationship Between Aneurysm Volume and Histologic Healing after Coil Embolization in Elastase-Induced Aneurysms: A Retrospective StudyAmerican Journal of Neuroradiology, 2007
- THE EFFECT OF VASCULAR RECONSTRUCTION DEVICE-ASSISTED COILING ON PACKING DENSITY, EFFECTIVE NECK COVERAGE, AND ANGIOGRAPHIC OUTCOMENeurosurgery, 2007
- Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic OutcomeAmerican Journal of Neuroradiology, 2007
- Packing Performance of Helical Guglielmi Detachable Coil (GDC) 18 in Intracranial Aneurysms: A Comparison with Helical GDC 10 Coils and Complex Trufill/Orbit CoilsAmerican Journal of Neuroradiology, 2007
- International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusionThe Lancet, 2005
- Evaluation of the Stability of Small Ruptured Aneurysms with a Small Neck after Embolization with Guglielmi Detachable Coils: Correlation between Coil Packing Ratio and Coil CompactionNeurosurgery, 2005
- Evaluation of Aneurysm Stability After Endovascular Embolization With Guglielmi Detachable Coils: Correlation Between Long-Term Stability and Volume Embolization RatioNeurologia medico-chirurgica, 2005
- Late angiographic follow-up review of surgically treated aneurysmsJournal of Neurosurgery, 1999
- Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coilsJournal of Neurosurgery, 1999
- Histological findings in giant aneurysms treated with Guglielmi detachable coilsJournal of Neurosurgery, 1995