Abstract
Patients after transcatheter aortic valve replacement (TAVR) and persistent severe mitral regurgitation (MR) are increasingly treated with percutaneous edge-to-edge mitral valve repair (PMVR). The impact of a former TAVR on PMVR procedures is not clear. We retrospectively analyzed 332 patients undergoing PMVR using the MitraClip system with respect to procedural and clinical outcome. 21 of these 332 patients underwent TAVR before PMVR. Intra-procedural transthoracic (TTE) and transesophageal echocardiograms (TEE) immediately before and after clip implantation as well as invasive hemodynamic measurements were evaluated. At baseline, we found a significantly smaller mitral valve anterior-posterior diameter in the TAVR cohort (p < 0.001). A reduction of MR by at least three grades was achieved in a smaller fraction in the TAVR cohort as compared to the cohort with a native aortic valve (p = 0.02). Accordingly, we observed a smaller post-procedural cardiac output in the TAVR cohort (p = 0.02). PMVR in patients who had a TAVR before, is associated with altered MR anatomy before and a reduced improvement of MR after the procedure. Future larger and prospective studies will have to determine, whether a previous TAVR influences long-term clinical outcome of patients undergoing PMVR.Keywords
This publication has 29 references indexed in Scilit:
- The German Aortic Valve Registry: 1-year results from 13 680 patients with aortic valve disease†European Journal of Cardio-Thoracic Surgery, 2014
- Predictors for prolonged hospital stay after transcatheter mitral valve repair with the MitraClip®Catheterization and Cardiovascular Interventions, 2014
- Real-Time Left Ventricular Pressure-Volume Loops During Percutaneous Mitral Valve Repair With the MitraClip SystemCirculation, 2013
- Acute Mitral Stenosis After Transcatheter Aortic Valve ImplantationJACC, 2012
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document†European Heart Journal, 2012
- Risk for Permanent Pacemaker After Transcatheter Aortic Valve Implantation: A Comprehensive Analysis of the LiteratureJournal of Cardiovascular Electrophysiology, 2011
- Influence of corevalve revalving system implantation on mitral valve functionCatheterization and Cardiovascular Interventions, 2011
- Percutaneous Repair or Surgery for Mitral RegurgitationNew England Journal of Medicine, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Quantitative Assessment of Severity of Mitral Regurgitation by Serial Echocardiography in a Multicenter Clinical Trial of Percutaneous Mitral Valve RepairThe American Journal of Cardiology, 2007