Temporary arc discharges resulting from glow-to-arc transitions and effect of power supply parameters

Authors:

Abstract
Values of the voltage and current of temporary arcs resulting from glow-to-arc transitions, for copper electrodes in air at atmospheric pressure for gap separations of 1, 2 and 3 mm, are presented in graphical form showing that the temporary arcs have a set of V-I characteristics from 0 · 1 A to 0 · 8 A and that they are similar to the static arc V-I characteristics. For a l mm gap at 0 · 1 A, the durations of transitions were short (0 · 1 ms). This caused an increase in discharge voltage to about 160 V, which was due to the short time available for the column to develop fully into an arc column. At 0 · 2 A for a 1 mm gap, the voltage was about 80 V and stayed constant up to about 0 · 8 A. The effect of source impedance, by changing the series resistance from 15kω to 2kω, was, for a 0 · 2 A 1 mm glow discharge, to increase the resulting temporary arc current from 0 · 22 A to 0 · 32 A. These results provide a means for predicting glow-to-arc transitions and show how to influence the resulting temporary arcs by using the electrical circuit parameters.

This publication has 5 references indexed in Scilit: