Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Authors:
- Karol Quelal AnaluisaKAKarol Quelal Analuisa
- Jason A. TriJTJason A. Tri
- Ikram U. HaqIHIkram U. Haq
- Amalia A. WelleAWAmalia A. Welle
- Atta BehfarABAtta Behfar
- Robert C. WardRWRobert C. Ward
- Fatima M. EzzeddineFEFatima M. Ezzeddine
- Elena G. TolkachevaETElena G. Tolkacheva
- Nicholas Y. TanNicholas Y. Tan
- Freddy Del-Carpio MunozFMFreddy Del-Carpio Munoz
- 1 October 2026
- journal article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (10) , e014954
Abstract
BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.Keywords
This publication has 17 references indexed in Scilit:
- Purkinje de-networking using a ripple map with a novel multielectrode mapping catheter for a ventricular fibrillation storm in a patient supported by an Impella device after an acute coronary syndromeHeartRhythm Case Reports, 2023
- Complexity analysis of electrical activity during endocardial and epicardial biventricular mapping of ventricular fibrillationJournal of Interventional Cardiac Electrophysiology, 2023
- Mapping and ablation of ventricular fibrillation substrateJournal of Interventional Cardiac Electrophysiology, 2023
- Catheter Ablation of Ventricular FibrillationCardiac Electrophysiology Clinics, 2022
- Novel insights into the substrate involved in maintenance of ventricular fibrillation: results from continuous multipolar mapping in a canine modelJournal of Interventional Cardiac Electrophysiology, 2022
- ESC working group on cardiac cellular electrophysiology position paper: relevance, opportunities, and limitations of experimental models for cardiac electrophysiology researchEP Europace, 2021
- The Evolution of Ventricular Scar Substrate Assessment by Using High-Resolution Mapping PlatformsJACC: Clinical Electrophysiology, 2021
- Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist DeviceJournal of Cardiovascular Electrophysiology, 2014
- Activation becomes highly organized during long-duration ventricular fibrillation in canine heartsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2010
- Effect of global ischemia and reperfusion during ventricular fibrillation in myopathic human heartsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2009