Optimization of K‐edge imaging with spectral CT
Authors:
- 8 October 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (11) , 6572-6579
Abstract
Purpose: Spectral/multienergy CT has the potential to distinguish different materials by K‐edge characteristics. K‐edge imaging involves the two energy bins on both sides of a K‐edge. The authors propose a K‐edge imaging optimization model to determine these two energy bins.Methods: K‐edge image contrast with spectral CT depends on the specifications of the two energy bins on both sides of a K‐edge in the attenuation profile of a relatively high atomic number material. The wider the energy bin width is, the lower the noise level is, and the poorer the reconstructed image contrast is. Here the authors introduce the signal difference to noise ratio (SDNR) criterion to optimize the energy bin widths on both sides of the K‐edge for the maximum SDNR.Results: The authors study K‐edge imaging with spectral CT, analyze the effect of K‐edge energy bins on the resultant image quality, and establish guidelines for the optimization of energy thresholds. In simulation, the authors demonstrate that our K‐edge imaging optimization approach maximizes SDNR in reconstructed images.Conclusions: This proposed approach can be readily generalized to deal with more general settings and determine the best energy bins for K‐edge imaging.Keywords
This publication has 27 references indexed in Scilit:
- Demonstration of enhanced iodine K-edge imaging using an energy-dispersive X-ray computed tomography system with a 25 mm/s-scan linear cadmium telluride detector and a single comparatorApplied Radiation and Isotopes, 2012
- Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)Inverse Problems, 2011
- MicroCT with energy-resolved photon-counting detectorsPhysics in Medicine & Biology, 2011
- Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging applicationPhysics in Medicine & Biology, 2011
- Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomographyPhysics in Medicine & Biology, 2008
- K-edge imaging in x-ray computed tomography using multi-bin photon counting detectorsPhysics in Medicine & Biology, 2007
- A spatial‐frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systemsMedical Physics, 1994
- The noise power spectrum of CT imagesPhysics in Medicine & Biology, 1987
- SNR and DQE analysis of broad spectrum X-ray imagingPhysics in Medicine & Biology, 1985
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976