The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain
- 26 December 2024
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 66 (1) , 125-133
Abstract
Background: Triple rule-out computed tomography angiography (CTA) provides imaging of the coronary arteries, pulmonary arteries, and thoracic aorta filled with contrast material (CM) to exclude or diagnose the pathologies of these three systems. Although dual rule-out adapted to exclude aortic and pulmonary pathologies. Iodinated CM may result in contrast-induced nephropathy, which lengthens hospital stay. Purpose: To compare image quality of dual/triple rule-out CTA by reducing the radiation dose by using relatively high mAs with less contrast material and low kilovoltage without affecting the diagnostic value. Methods: We acquired standard dual/triple rule-out CTA 120 kilovoltage peak (kVp) with 95 mL contrast material. The low-dose group acquired 80 Kvp with total 60 contrast material. There were 91 patients in the standard-dose group and 88 patients in the low-dose group. Results: Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated separately. There was no significant difference in CNR values between the two groups in the aorta and pulmonary and coronary arteries; however, a significant difference was found in SNR values. In subjective image quality evaluation, no significant difference was found between the standard- and low-dose patients. The radiation dose was reduced by 63.80% and the contrast material by 31.5% in the low-dose group in comparison to the standard dose. Conclusion: Our study showed that dual/triple rule-out CTA can be performed with low-dose radiation and low-volume contrast material. Low-dose CTA may be preferred in emergencies situations that patients with borderline renal function tests or the risk group.Keywords
This publication has 14 references indexed in Scilit:
- The use of 80 kV versus 100 kV in pulmonary CT angiography: An evaluation of the impact on radiation dose and image quality on two CT scannersRadiography, 2019
- Reducing contrast medium volume and tube voltage in CT angiography of the pulmonary arteryClinical Radiology, 2016
- Low contrast media volume in pre-TAVI CT examinationsEuropean Radiology, 2015
- Chest CT examinations in patients presenting with acute chest pain: a pictorial reviewInsights into Imaging, 2015
- Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility studyBritish Journal of Radiology, 2015
- Image Quality and Feasibility of an Ultralow-dose High-pitch Helical Triple–rule-out Computed Tomography Angiography Acquired in the Caudocranial DirectionJournal of Thoracic Imaging, 2014
- Reduction of contrast medium volume in abdominal aorta CTA: Multiphasic injection technique versus a test bolus volumeEuropean Journal of Radiology, 2013
- Coronary computed tomography and triple rule out CT in patients with acute chest pain and an intermediate cardiac risk profile. Part 1: Impact on patient managementEuropean Journal of Radiology, 2013
- Comparison of Radiation Dose and Image Quality of Triple-Rule-Out Computed Tomography Angiography Between Conventional Helical Scanning and a Strategy Incorporating Sequential ScanningThe American Journal of Cardiology, 2011
- Strategies for CT Radiation Dose OptimizationRadiology, 2004