An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform
- 1 November 2009
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 297 (5) , H1956-H1963
Abstract
We developed a new technique to mathematically transform a peripheral artery pressure (PAP) waveform distorted by wave reflections into the physiologically more relevant aortic pressure (AP) waveform. First, a transfer function relating PAP to AP is defined in terms of the unknown parameters of a parallel tube model of pressure and flow in the arterial tree. The parameters are then estimated from the measured PAP waveform along with a one-time measurement of the wave propagation delay time between the aorta and peripheral artery measurement site (which may be accomplished noninvasively) by exploiting preknowledge of aortic flow. Finally, the transfer function with its estimated parameters is applied to the measured waveform so as to derive the AP waveform. Thus, in contrast to the conventional generalized transfer function, the transfer function is able to adapt to the intersubject and temporal variability of the arterial tree. To demonstrate the feasibility of this adaptive transfer function technique, we performed experiments in 6 healthy dogs in which PAP and reference AP waveforms were simultaneously recorded during 12 different hemodynamic interventions. The AP waveforms derived by the technique showed agreement with the measured AP waveforms (overall total waveform, systolic pressure, and pulse pressure root mean square errors of 3.7, 4.3, and 3.4 mmHg, respectively) statistically superior to the unprocessed PAP waveforms (corresponding errors of 8.6, 17.1, and 20.3 mmHg) and the AP waveforms derived by two previously proposed transfer functions developed with a subset of the same canine data (corresponding errors of, on average, 5.0, 6.3, and 6.7 mmHg).Keywords
This publication has 17 references indexed in Scilit:
- Arterial transfer functions: background, applications and reservationsJournal Of Hypertension, 2008
- Stability of Ventricular Repolarization in Conscious Dogs with Chronic Atrioventricular Dissociation and His-Bundle PacingPacing and Clinical Electrophysiology, 2004
- Central Pulse Pressure and Mortality in End-Stage Renal DiseaseHypertension, 2002
- A New Model-Based Method of Reconstructing Central Aortic Pressure from Peripheral Arterial Pressure.The Japanese Journal of Physiology, 2001
- Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometryIEEE Transactions on Biomedical Engineering, 1999
- Physical basis of pressure transfer from periphery to aorta: a model-based studyAmerican Journal of Physiology-Heart and Circulatory Physiology, 1998
- If Dr. Bazett Had Had a Computer…Pacing and Clinical Electrophysiology, 1996
- An analysis of the relationship between central aortic and peripheral upper limb pressure waves in manEuropean Heart Journal, 1993
- Measurement of pulse-wave velocity using a beat-sampling techniqueAnnals of Biomedical Engineering, 1988
- Regional pulse-wave velocity in the arterial tree.Journal of Applied Physiology, 1968