Ground-based calibration and characterization of LaBr3-SiPM-based gamma-ray detector on GECAM satellite: 8–160 keV
- 1 September 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 525 (3) , 3399-3412
Abstract
As the main detector of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor mission (GECAM), the calibration of the energy response and detection efficiency of the gamma-ray detector (GRD) is the main content of the ground-based calibration. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8–160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal ($\rm {LaBr_3}$). The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analysed in detail. We show that the calibration campaign is comprehensive, the detector performance meets the flight requirements, and the calibration results generally agree with simulations as expected. The detector’s model was corrected by the ground-based calibration, which led to the establishment of the calibration data base.Keywords
Funding Information
- National Natural Science Foundation of China (11775251)
- Chinese Academy of Sciences (XDA 15360100, XDA 15360102)
This publication has 18 references indexed in Scilit:
- Development of new large calorimeter prototypes based on LaBr(Ce) and LYSO crystals coupled to silicon photomultipliers: A direct comparisonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Radiation damage of prototype SiPMs for the CMS HCAL Barrel phase I upgradeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- A low-energy sensitive compact gamma-ray detector based on LaBr3 and SiPM for GECAMJournal of Instrumentation, 2018
- LEGe detector intrinsic efficiency calibration for parallel incident photonsApplied Radiation and Isotopes, 2016
- Introduction to a calibration facility for hard X-ray detectorsExperimental Astronomy, 2014
- Energy resolution and related charge carrier mobility in LaBr3:Ce scintillatorsJournal of Applied Physics, 2013
- Study of 138La radioactive decays using LaBr3 scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Nonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiationJournal of Physics: Condensed Matter, 2010
- Precision crystal calorimeters in high-energy physics: past, present, and future2008
- Comparison of LaBr3:Ce and NAI(Tl) scintillators for radio-isotope identification devicesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007