Single‐shot magnetic resonance spectroscopic imaging with partial parallel imaging
Open Access
- 18 December 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (3) , 541-547
Abstract
A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton–echo‐planar‐spectroscopic‐imaging (PEPSI) is introduced that measures two‐dimensional metabolite maps in a single excitation. Echo‐planar spatial–spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k‐space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single‐shot MRSI at short TE was evaluated in phantoms and in vivo on a 3‐T whole‐body scanner equipped with a 12‐channel array coil. Four‐step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 × 16 spatial matrix with a 390‐Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g‐factor–related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N‐acetyl‐aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE‐accelerated PEPSI. Cramer–Rao lower bounds were comparable to those obtained with conventional SENSE‐accelerated PEPSI at the same voxel size and measurement time. This single‐shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. Magn Reson Med, 2009.Keywords
Funding Information
- National Institutes of Health (R01 HD040712, R01 NS037462, R01 EB000790-04, P41 RR14075, R21 EB007298, R01 DA14178-01)
- Mental Illness and Neuroscience Discovery Institute
- Taiwan National Science Council (NSC-95-2221-E-002-179, NSC 96-2320-B-002-085)
- National Health Research Institute Taiwan (E29C97N)
This publication has 37 references indexed in Scilit:
- Accelerated 3D echo-planar spectroscopic imaging at 4 Tesla using modified blipped phase-encodingMagnetic Resonance in Medicine, 2007
- Proton echo‐planar spectroscopic imaging of J‐coupled resonances in human brain at 3 and 4 TeslaMagnetic Resonance in Medicine, 2007
- Fast 3D 1H spectroscopic imaging at 3 Tesla using spectroscopic missing‐pulse SSFP with 3D spatial preselectionMagnetic Resonance in Medicine, 2006
- Signal‐to‐noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo‐planar spectroscopic imagingMagnetic Resonance in Medicine, 2006
- Real-time metabolic imagingProceedings of the National Academy of Sciences, 2006
- Parallel spectroscopic imaging with spin‐echo trainsMagnetic Resonance in Medicine, 2003
- Echo‐Planar Diffusion Spectroscopic ImagingMagnetic Resonance in Medicine, 1995
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- Fast proton spectroscopic imaging using the sliced k‐space methodMagnetic Resonance in Medicine, 1993
- Fast proton spectroscopic imaging of human brain using multiple spin‐echoesMagnetic Resonance in Medicine, 1993