Ramsey-comb precision spectroscopy in xenon at vacuum ultraviolet wavelengths produced with high-order harmonic generation
- 18 May 2020
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review A
- Vol. 101 (5) , 052509
Abstract
The remarkable progress in the field of laser spectroscopy induced by the invention of the frequency-comb laser has enabled many high-precision tests of fundamental theory and searches for new physics. Extending frequency-comb-based spectroscopy techniques to the vacuum and extreme ultraviolet spectral range would enable frequency measurements of transitions in, e.g., heavier hydrogen-like systems and open up new possibilities for tests of quantum electrodynamics and measurements of fundamental constants. The two main approaches, full-repetition rate up-conversion in a resonator and two-pulse amplification and up-conversion for the Ramsey-comb technique, rely on high-order harmonic generation (HHG), which is known to induce spurious phase shifts from plasma formation. After our initial report [ Phys. Rev. Lett. 123, 143001 (2019)], in this article we give a detailed account of how the Ramsey-comb spectroscopy technique is used to probe the dynamics of this plasma with high precision and enables accurate spectroscopy in the vacuum ultraviolet. It is based on recording Ramsey fringes that track the phase evolution of a superposition state in xenon atoms excited by two up-converted frequency-comb laser pulses. In this manner, phase shifts up to 1 rad induced by the HHG process could be observed at nanosecond timescales with mrad-level accuracy at 110 nm. We also show that such phase shifts can be reduced to a negligible level of a few mrad. As a result, we were able to measure the transition in at 110 nm (the seventh harmonic of 770 nm) with sub-MHz accuracy, leading to a transition frequency of . This value is times more precise than the previous determination and the fractional accuracy of is 3.6 times better than the previous best spectroscopic measurement using high-order harmonic generation. Additionally, the isotope shifts between and two other isotopes ( and ) were determined with an accuracy of 420 kHz. The method can be readily extended to achieve kHz-level accuracy by increasing the pulse delay, e.g., to measure the transition in . Therefore, the Ramsey-comb method shows great promise for high-precision spectroscopy of targets requiring vacuum ultraviolet and extreme ultraviolet wavelengths.
Keywords
All Related Versions
Funding Information
- Vrije Universiteit Amsterdam
- European Research Council (695677)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (16MYSTP)
This publication has 60 references indexed in Scilit:
- Benchmarking Theory with an Improved Measurement of the Ionization and Dissociation Energies ofPhysical Review Letters, 2019
- Highly charged ions: Optical clocks and applications in fundamental physicsReviews of Modern Physics, 2018
- CODATA recommended values of the fundamental physical constants: 2014Reviews of Modern Physics, 2016
- Probing QED and fundamental constants through laser spectroscopy of vibrational transitions in HD+Nature Communications, 2016
- Muonic Hydrogen and the Proton Radius PuzzleAnnual Review of Nuclear and Particle Science, 2013
- Proton Structure from the Measurement of 2S-2P Transition Frequencies of Muonic HydrogenScience, 2013
- Improved Measurement of the HydrogenTransition FrequencyPhysical Review Letters, 2011
- The size of the protonNature, 2010
- High Precision Wavelength Measurements of QED-Sensitive Forbidden Transitions in Highly Charged Argon IonsPhysical Review Letters, 2003
- Lamb Shift in Hydrogenlike Uranium Measured on Cooled, Decelerated Ion BeamsPhysical Review Letters, 2000