PET Myocardial Blood Flow for Post-transplant Surveillance and Cardiac Allograft Vasculopathy in Heart Transplant Recipients
- 24 October 2022
- journal article
- review article
- Published by Springer Nature in Current Cardiology Reports
- Vol. 24 (12) , 1865-1871
Abstract
Purpose of Review Cardiac allograft vasculopathy (CAV) is a late-occurring complication of heart transplantation significantly limiting overall graft survival. In the last few years, evidence has been growing about the use of positron emission tomography (PET) myocardial perfusion imaging with integrated myocardial blood flow (MBF) quantification in heart transplant recipients. Recent Findings Multiple studies have demonstrated that PET MBF assessment can be utilized to establish the diagnosis of CAV noninvasively and can be employed for prognostication. PET MBF quantification has also helped to define the link between transplant rejection and CAV. In addition, limited data suggests that PET MBF quantification can be used in heart transplant patients for serial monitoring of CAV. Summary PET myocardial perfusion imaging integrating MBF quantification shows great promise for the evaluation of CAV with good diagnostic and prognostic performance.Keywords
This publication has 32 references indexed in Scilit:
- Interacting Mechanisms in the Pathogenesis of Cardiac Allograft VasculopathyArteriosclerosis, Thrombosis, and Vascular Biology, 2014
- OCT Assessment of Allograft Vasculopathy in Heart Transplant RecipientsJACC: Cardiovascular Imaging, 2012
- International Society for Heart and Lung Transplantation working formulation of a standardized nomenclature for cardiac allograft vasculopathy—2010The Journal of Heart and Lung Transplantation, 2010
- PET Assessment of Myocardial Perfusion Reserve Inversely Correlates with Intravascular Ultrasound Findings in Angiographically Normal Cardiac Transplant RecipientsJournal of Nuclear Medicine, 2010
- Acute Cellular Rejection and the Subsequent Development of Allograft Vasculopathy After Cardiac TransplantationThe Journal of Heart and Lung Transplantation, 2009
- Prognostic Impact of Microvasculopathy on Survival After Heart TransplantationCirculation, 2007
- Effects of Cardiac Allograft Vasculopathy on Myocardial Blood Flow, Vasodilatory Capacity, and Coronary VasomotionCirculation, 1997
- Myocardial blood flow at rest and during pharmacological vasodilation in cardiac transplants during and after successful treatment of rejection.Circulation, 1994
- Influence of age and hemodynamics on myocardial blood flow and flow reserve.Circulation, 1993
- Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of "angiographically silent" intimal thickening.Circulation, 1992