Interaction between diurnal variations of intraocular pressure, pachymetry, and corneal response to an air puff: Preliminary evidence
Authors:
- Miguel A. Ariza-GraciaMAMiguel A. Ariza-Gracia
- David P. PiñeroDPDavid P. Piñero
- José F. RodriguezJRJosé F. Rodriguez
- Rafael J. Pérez-CambrodíRPRafael J. Pérez-Cambrodí
- Begoña CalvoBCBegoña Calvo
- 1 January 2015
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 3 (1) , 12-15
Abstract
Diurnal changes in corneal geometry, pachymetry, and intraocular pressure (IOP) in a healthy eye were recorded. The deformation response to an air puff was simulated using 3 levels of corneal stiffness. The response was dependent on IOP and pachymetry and not only on the biomechanical properties of the cornea. Similarly, the maximum variability due to the diurnal changes in pachymetry and IOP in the corneal displacement generated by the air puff was found to reach 5%. Therefore, diurnal changes in IOP and corneal thickness were able to induce some variability in the air puff–based corneal deformation response. This potential variability should be considered when the biomechanical properties of the cornea are analyzed with air-puff devices.Supported by the European Union’s Seventh Framework Program managed by Research Executive Agency under Grant Agreement number FP7-SME-2013 606634 (POPCORN Project) and the Spanish Ministry of Economy and Competitiveness (DPI2011-27939-C02-01)Keywords
This publication has 11 references indexed in Scilit:
- Corneal Viscoelastic Properties from Finite-Element Analysis of In Vivo Air-Puff DeformationPLOS ONE, 2014
- In vivo characterization of corneal biomechanicsJournal of Cataract & Refractive Surgery, 2014
- Associations Between Diurnal Changes in Goldmann Tonometry, Corneal Geometry, and Ocular Response Analyzer ParametersCornea, 2012
- Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular PressureOptometry and Vision Science, 2008
- A Viscoelastic Biomechanical Model of the Cornea Describing the Effect of Viscosity and Elasticity on HysteresisInvestigative Ophthalmology & Visual Science, 2008
- Intraoffice Variability of Corneal Biomechanical Parameters and Intraocular Pressure (IOP)Optometry and Vision Science, 2008
- Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetryJournal of Cataract & Refractive Surgery, 2008
- Effect of 24-Hour Corneal Biomechanical Changes on Intraocular Pressure MeasurementInvestigative Ophthalmology & Visual Science, 2006
- Repeatability and Reproducibility of Central Corneal Thickness Measurement With Pentacam, Orbscan, and UltrasoundOptometry and Vision Science, 2005
- Biomechanical Modeling of Refractive Corneal SurgeryJournal of Biomechanical Engineering, 2005