Real and Pseudoaccommodation in Accommodative Lenses
Open Access
- 18 September 2011
- journal article
- review article
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2011, 1-8
Abstract
In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of “pseudoaccommodation.” Pseudo accommodative capability can be linked to monofocal IOL’s as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully “cure” presbyopia.Keywords
This publication has 53 references indexed in Scilit:
- US FDA Clinical Trial of the Tetraflex Potentially Accommodating IOL: Comparison to Concurrent Age-Matched Monofocal ControlsJournal of Refractive Surgery, 2010
- Biconvex posterior chamber accommodating intraocular lens implantation after cataract surgery: Long-term outcomesJournal of Cataract & Refractive Surgery, 2010
- Repeatability of Reading Ability Indices in Subjects with Impaired VisionInvestigative Ophthalmology & Visual Science, 2009
- Spherical aberration, visual performance and pseudoaccommodation of eyes implanted with different aspheric intraocular lensClinical & Experimental Ophthalmology, 2008
- Restoration of accommodation: surgical options for correction of presbyopiaClinical and Experimental Optometry, 2008
- Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diametersJournal of Cataract & Refractive Surgery, 2006
- A comparison of accommodation amplitudes in pseudophakic eyes measured with three different methodsEye, 2006
- Clinical evaluation of the Crystalens AT-45 accommodating intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Comparison of amplitude of apparent accommodation in pseudophakic eyes with that of normal accommodation in phakic eyes in various age groupsEye, 2005
- Myopic astigmatism and presbyopia trialAmerican Journal of Ophthalmology, 2003