A Monte Carlo study of the relative biological effectiveness in surface brachytherapy
- 17 June 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 49 (8) , 5576-5588
Abstract
Purpose This work aims to simulate clustered DNA damage from ionizing radiation and estimate the relative biological effectiveness (RBE) for radionuclide (rBT)- and electronic (eBT)-based surface brachytherapy through a hybrid Monte Carlo (MC) approach, using realistic models of the sources and applicators. Methods Damage from ionizing radiation has been studied using the Monte Carlo Damage Simulation algorithm using as input the primary electron fluence simulated using a state-of-the-art MC code, PENELOPE-2018. Two Ir-192 rBT applicators, Valencia and Leipzig, one Co-60 source with a Freiburg Flap applicator (reference source), and two eBT systems, Esteya and INTRABEAM, have been included in this study implementing full realizations of their geometries as disclosed by the manufacturer. The role played by filtration and tube kilovoltage has also been addressed. Results For rBT, an RBE value of about 1.01 has been found for the applicators and phantoms considered. In the case of eBT, RBE values for the Esteya system show an almost constant RBE value of about 1.06 for all depths and materials. For INTRABEAM, variations in the range of 1.12-1.06 are reported depending on phantom composition and depth. Modifications in the Esteya system, filtration, and tube kilovoltage give rise to variations in the same range. Conclusions Current clinical practice does not incorporate biological effects in surface brachytherapy. Therefore, the same absorbed dose is administered to the patients independently on the particularities of the rBT or eBT system considered. The almost constant RBE values reported for rBT support that assumption regardless of the details of the patient geometry, the presence of a flattening filter in the applicator design, or even significant modifications in the photon energy spectra above 300 keV. That is not the case for eBT, where a clear dependence on the eBT system and the characteristics of the patient geometry are reported. A complete study specific for each eBT system, including detailed applicator characteristics (size, shape, filtering, among others) and common anatomical locations, should be performed before adopting an existing RBE value.Keywords
This publication has 48 references indexed in Scilit:
- Relative Biologic Effectiveness (RBE) of 50 kV X-rays Measured in a Phantom for Intraoperative Tumor-Bed IrradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapyBrachytherapy, 2012
- Contact radiotherapy using a 50kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurementsRadiation Physics and Chemistry, 2012
- Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTROMedical Physics, 2012
- Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate sourceJournal of Contemporary Brachytherapy, 2012
- Dosimetry revisited for the HDR brachytherapy source model mHDR‐v2Medical Physics, 2010
- Relative biological effectiveness of photon energies used in brachytherapy and intraoperative radiotherapy techniques for two breast cancer cell linesActa Oncologica, 2010
- A dosimetric study of Leipzig applicatorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Soft X-ray Dosimetry and RBE for Survival of Chinese Hamster V79 CellsInternational Journal of Radiation Biology, 1988
- X-ray incoherent scattering total cross sections and energy-absorption cross sections by means of simple calculation routinesPhysical Review A, 1983