Use of intrathoracic pressure regulation therapy in breathing patients for the treatment of hypotension secondary to trauma
Authors:
- Victor A. ConvertinoVictor A. Convertino
- Brent A. ParquetteBPBrent A. Parquette
- David A. WamplerDWDavid A. Wampler
- Craig A. ManifoldCMCraig A. Manifold
- David A. LindstromDLDavid A. Lindstrom
- Lori L. BolandLBLori L. Boland
- Nathan T. BurkhartNBNathan T. Burkhart
- Keith G. LurieKLKeith G. Lurie
- Charles J. LickCLCharles J. Lick
Open Access
- 30 October 2017
- journal article
- research article
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 25 (1) , 105
Abstract
Intrathoracic pressure regulation (IPR) therapy has been shown to increase blood pressure in hypotensive patients. The potential value of this therapy in patients with hypotension secondary to trauma with bleeding is not well understood. We hypothesized that IPR would non-invasively and safely enhance blood pressure in spontaneously breathing patients with trauma-induced hypotension. This prospective observational cohort study assessed vital signs from hypotensive patients with a systolic blood pressure (SBP) ≤90 mmHg secondary to trauma treated with IPR (ResQGARD™, ZOLL Medical) by pre-hospital emergency medical personnel in three large US metropolitan areas. Upon determination of hypotension, facemask-based IPR was initiated as long as bleeding was controlled. Vital signs were recorded before, during, and after IPR. An increased SBP with IPR use was the primary study endpoint. Device tolerance and ease of use were also reported. A total of 54 patients with hypotension secondary to trauma were treated from 2009 to 2016. The mean ± SD SBP increased from 80.9 ± 12.2 mmHg to 106.6 ± 19.2 mmHg with IPR (p < 0.001) and mean arterial pressures (MAP) increased from 62.2 ± 10.5 mmHg to 81.9 ± 16.6 mmHg (p < 0.001). There were no significant changes in mean heart rate or oxygen saturation. Approximately 75% of patients reported moderate to easy tolerance of the device. There were no safety concerns or reported adverse events. These findings support the use of IPR to treat trauma-induced hypotension as long as bleeding has been controlled.Keywords
Funding Information
- Medical Research and Materiel Command (W81XWH-12-2-0027)
This publication has 23 references indexed in Scilit:
- “Fluidless” resuscitation with permissive hypotension via impedance threshold device therapy compared with normal saline resuscitation in a porcine model of severe hemorrhageJournal of Trauma and Acute Care Surgery, 2013
- Use of respiratory impedance in prehospital care of hypotensive patients associated with hemorrhage and traumaJournal of Trauma and Acute Care Surgery, 2012
- An Impedance Threshold Device Increases Blood Pressure in Hypotensive PatientsThe Journal of Emergency Medicine, 2011
- Optimizing the Respiratory Pump: Harnessing Inspiratory Resistance to Treat Systemic HypotensionRespiratory Care, 2011
- Management of bleeding following major trauma: an updated European guidelineCritical Care, 2010
- Breathing through an inspiratory threshold device improves stroke volume during central hypovolemia in humansJournal of Applied Physiology, 2008
- Inspiratory resistance delays the reporting of symptoms with central hypovolemia: association with cerebral blood flowAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2007
- Inspiratory resistance maintains arterial pressure during central hypovolemia: Implications for treatment of patients with severe hemorrhageCritical Care Medicine, 2007
- Increased impedance to inspiration ameliorates hemodynamic changes associated with movement to upright posture in orthostatic hypotension: A randomized blinded pilot studyHeart Rhythm, 2007
- Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigsResuscitation, 2006