Cross-validation of the high-capacity tensiometer and thermocouple psychrometer for continuous monitoring of xylem water potential in saplings
Open Access
- 10 September 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Experimental Botany
- Vol. 73 (1) , 400-412
Abstract
The pressure chamber, the most popular method used to measure xylem water potential, is a discontinuous and destructive technique and is therefore not suitable for automated monitoring. Continuous non-destructive monitoring could until very recently be achieved only by use of the thermocouple psychrometer (TP). Here we present the high-capacity tensiometer (HCT) as an alternative method for continuous non-destructive monitoring. This provided us with a unique chance to cross-validate the two instruments by installing them simultaneously on the same sapling stem. The HCT and the TP showed excellent agreement for xylem water potential less than –0.5 MPa. Response to day/night cycles and watering was remarkably in phase, indicating excellent response time of both instruments despite substantially different working principles. For xylem water potential greater than –0.5 MPa, the discrepancies sometimes observed between the HCT and TP were mainly attributed to the kaolin paste used to establish contact between the xylem and the HCT, which becomes hydraulically poorly conductive in this range of water potential once dried beyond its air-entry value and subsequently re-wetted. Notwithstanding this limitation, which can be overcome by selecting a clay paste with higher air-entry value, the HCT has been shown to represent a valid alternative to the TP.Keywords
Funding Information
- European Commission (H2020-MSCA-ITN-2015-675762)
This publication has 22 references indexed in Scilit:
- Examination and parameterization of the root water uptake model from stem water potential and sap flow measurementsHydrological Processes, 2012
- A water retention model for deformable soilsGéotechnique, 2009
- Monitoring plant and soil water status: established and novel methods revisited and their relevance to studies of drought toleranceJournal of Experimental Botany, 2006
- Calibration of tensiometer for direct measurement of matric suctionGéotechnique, 2003
- The essentials of direct xylem pressure measurementPlant, Cell & Environment, 2001
- A new instrument for the measurement of soil moisture suctionGéotechnique, 1993
- A new stem hygrometer, corrected for temperature gradients and calibrated against the pressure bombPlant, Cell & Environment, 1984
- Frictional Potential Losses and Total Water Potential in Plants: a Re-evaluationJournal of Experimental Botany, 1973
- Psychrometric Measurement of Soil Water Potential: Temperature and Bulk Density EffectsSoil Science Society of America Journal, 1971
- Osmotic coefficients and water potentials of sodium chloride solutions from 0 to 40°CAustralian Journal of Chemistry, 1967