Abstract
Inactivation of Salmonella serovar Enteritidis and Salmonella serovar Typhimurium by pulsed electric fields has been investigated. A tertiary model based on the Weibull distribution ( n = 0.262) and on a new parameter ( Z PEF ), accurately described the kinetics of inactivation of these microorganisms among 15 and 28 kV/cm. In the range of 19 to 28 kV/cm, this model also described previously published data of inactivation of serovar Senftenberg when the n value was set at 0.437. The Z PEF value for the 3 Salmonella serovars was 15.787 kV/cm. From 19 to 28 kV/cm, the time to inactivate 5 Log 10 cycles of the population of serovar Enteritidis was 2.06 and 2.66 times lower than that to inactivate serovar Typhimurium and serovar Senftenberg, respectively.

This publication has 21 references indexed in Scilit: