Effects of isoflurane anaesthesia depth and duration on renal function measured with [99mTc]Tc-mercaptoacetyltriglycine SPECT in mice
Open Access
- 5 January 2024
- journal article
- research article
- Published by Springer Nature in EJNMMI Research
- Vol. 14 (1) , 1-10
Abstract
Background: The influence of anaesthetic depth and the potential influence of different anaesthetic beds and thus different handling procedures were investigated in 86 severe combined immunodeficient (SCID) mice using semi-stationary dynamic single photon emission computed tomography (SPECT) for kidney scintigraphy. Therefore, isoflurane concentrations were adjusted using respiratory rate for low (80–90 breath/min) and deep anaesthesia (40–45 breath/min). At low anaesthesia, we additionally tested the influence of single bed versus 3-mouse bed hotel; the hotel mice were anaesthetized consecutively at ~ 30, 20, and 10 min before tracer injections for positions 1, 2, and 3, respectively. Intravenous [99mTc]Tc-MAG3 injection of ~ 28 MBq was performed after SPECT start. Time-activity curves were used to calculate time-to-peak (Tmax), T50 (50% clearance) and T25 (75% clearance). Results: Low and deep anaesthesia corresponded to median isoflurane concentrations of 1.3% and 1.5%, respectively, with no significant differences in heart rate (p = 0.74). Low anaesthesia resulted in shorter aortic blood clearance half-life (p = 0.091) and increased relative renal tracer influx rate (p = 0.018). A tendency toward earlier Tmax occurred under low anaesthesia (p = 0.063) with no differences in T50 (p = 0.40) and T25 (p = 0.24). Variance increased with deep anaesthesia. Compared to single mouse scans, hotel mice in position 1 showed a delayed Tmax, T50, and T25 (p < 0.05 each). Furthermore, hotel mice in position 1 showed delayed Tmax versus position 3, and delayed T50 and T25 versus position 2 and 3 (p < 0.05 each). No difference occurred between single bed and positions 2 (p = 1.0) and 3 (p = 1.0). Conclusions: Deep anaesthesia and prolonged low anaesthesia should be avoided during renal scintigraphy because they result in prolonged blood clearance half-life, delayed renal influx and/or later Tmax. Vice versa, low anaesthesia with high respiratory rates of 80–90 rpm and short duration (≤ 20 min) should be preferred to obtain representative data with low variance.Keywords
Funding Information
- Charité 3R: Replace, Reduce, Refine
- Technologiestiftung Berlin
- Ruth-Jeschke-Gedenkstipendium, Charité – Universitätsmedizin Berlin
- Charité - Universitätsmedizin Berlin
This publication has 47 references indexed in Scilit:
- Effects of Anesthesia and Species on the Uptake or Binding of Radioligands In Vivo in the Göttingen MinipigBioMed Research International, 2013
- Anaesthesia and physiological monitoring during in vivo imaging of laboratory rodents: considerations on experimental outcomes and animal welfareEJNMMI Research, 2012
- The Circadian Clock in the KidneyJournal of the American Society of Nephrology, 2011
- The Effects of Neonatal Isoflurane Exposure in Mice on Brain Cell Viability, Adult Behavior, Learning, and MemoryAnesthesia & Analgesia, 2009
- Recommendations on the Use of 18F-FDG PET in OncologyJournal of Nuclear Medicine, 2008
- COMPARISON BETWEEN THE EFFECTS ON HEMODYNAMIC RESPONSES OF CENTRAL AND PERIPHERAL INFUSIONS OF HYPERTONIC NACL DURING HEMORRHAGE IN CONSCIOUS AND ISOFLURANCE-ANESTHETIZED SHEEPShock, 2006
- Isoflurane alters proximal tubular cell susceptibility to toxic and hypoxic forms of attackKidney International, 1999
- Evaluation of gamma camera-based measurement of individual kidney function using iodine-123 orthoiodohippurateEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- Effects of Halothane and Isoflurane on Ventilation and Occlusion PressureAnesthesiology, 1994
- Renal Effects and Metabolism of Isoflurane in ManAnesthesiology, 1974