Partial Discharge Signal De-noising in Power Transformer by Applying Radial Basis Function Network
Preprint
- 9 November 2022
- preprint
- Published by Springer Nature in Research Square
Abstract
The noise interferes with the measuring equipment installed in transformer stations and results in technical challenges for utility engineers. Sensors are mounted on transformers, to measure partial discharge (PD) signals, but the noise deforms the PD signals. In this paper, the noise removal from PD signal of power transformers is performed by a radial basis function (RBF) neural network. The CST software is used to simulate a transformer, PD and noise. Also, a laboratory model is used to generate the PD and noise signals. The simulation and measurement results are presented and discussed. It is shown that the proposed method is a good technique for noise removal from PD signals.Keywords
All Related Versions
This publication has 16 references indexed in Scilit:
- Robust Classification of Partial Discharges in Transformer Insulation Based on Acoustic Emissions Detected Using Fiber Bragg GratingsIEEE Sensors Journal, 2018
- Denoising of acoustic partial discharge signals corrupted with random noiseIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- GLRT-Based Mitigation of Partial Discharge Effect on Detection of Radial Deformation of Transformer HV Winding Using SAR Imaging MethodIEEE Sensors Journal, 2016
- Simultaneous location of two partial discharge sources in power transformers based on acoustic emission using the modified binary partial swarm optimisation algorithmIET Science, Measurement & Technology, 2013
- A novel method for ultra-high-frequency partial discharge localization in power transformers using the particle swarm optimization algorithmIEEE Electrical Insulation Magazine, 2013
- Location of PD sources in power transformers by UHF and acoustic measurementsIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Electro-acoustic detection, identification and location of partial discharge sources in oil-paper insulation systemsIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretationIEEE Electrical Insulation Magazine, 2005
- Hyper Radial Basis Function Neural Networks for Interference Cancellation with Nonlinear Processing of Reference SignalDigital Signal Processing, 2001
- Nonlinear blind source separation using a radial basis function networkIEEE Transactions on Neural Networks, 2001