A method for calculating 16o/18o peptide ion ratios for the relative quantification of proteomes
- 1 April 2004
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 15 (4) , 437-445
Abstract
A method is described for the identification and relative quantification of proteomes using accurate mass tags (AMT) generated by nLC-dual ESI-FT-ICR-MS on a 7T instrument in conjunction with stable isotope labeling using 16O/18O ratios. AMTs were used for putative peptide identification, followed by confirmation of peptide identity by tandem mass spectrometry. For a combined set of 58 tryptic peptides from bovine serum albumin (BSA) and human transferrin, a mean mass measurement accuracy of 1.9 ppm ±0.94 ppm (CIM99%) was obtained. This subset of tryptic peptides was used to measure 16O/18O ratios of 0.36±0.09 (CIM99%) for BSA (μ=0.33) and 1.48±0.47 (CIM99%) for transferrin (μ=1.0) using a method for calculating 16O/18O ratios from overlapping isotopic multiplets arising from mixtures of 16O, 18O1, and 18O2 labeled C-termini. The model amino acid averagine was used to calculate a representative molecular formula for estimating and subtracting the contributions of naturally occurring isotopes solely as a function of peptide molecular weight. The method was tested against simulated composite 16O/18O spectra where peptide molecular weight, 16O/18O ratio, 18O1/18O2 ratios, and number of sulfur atoms were varied. Relative errors of 20% or less were incurred when the 16O/18O ratios were less than three, even for peptides where the number of sulfur atoms was over- or under-estimated. These data demonstrate that for biomarker discovery, it is advantageous to label the proteome representing the disease state with 18O; and the method is not sensitive to variations in 18O1/18O2 ratio. This approach allows a comprehensive differentiation of expression levels and tentative identification via AMTs, followed by targeted analysis of over- and under-expressed peptides using tandem mass spectrometry, for applications such as the discovery of disease biomarkers.Keywords
This publication has 26 references indexed in Scilit:
- Stable isotope-coded proteomic mass spectrometryCurrent Opinion in Biotechnology, 2003
- The Human Plasma ProteomeMolecular & Cellular Proteomics, 2002
- Comparative proteomics based on stable isotope labeling and affinity selectionJournal of Mass Spectrometry, 2002
- Inverse 18O Labeling Mass Spectrometry for the Rapid Identification of Marker/Target ProteinsAnalytical Chemistry, 2001
- Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of AdenovirusAnalytical Chemistry, 2001
- Proteome analysis using selective incorporation of isotopically labeled amino acidsJournal of the American Society for Mass Spectrometry, 2000
- Quantitative analysis of complex protein mixtures using isotope-coded affinity tagsNature Biotechnology, 1999
- Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometryElectrophoresis, 1996
- C-terminal peptide identification by fast atom bombardment mass spectrometryBiochemical Journal, 1988
- Preparation of stable isotope-incorporated peptide internal standards for field desorption mass spectrometry quantification of peptides in biologic tissueJournal of Mass Spectrometry, 1983