A Simplified Thin-Layer Chromatography System for the Detection of Commonly Abused Basic Drugs
Authors:
- 1 September 1987
- journal article
- research article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 24 (5) , 508-510
Abstract
A simple method for the detection of drugs of abuse and their metabolites in urine is described. By extraction of urine (20 mL) with a buffered ToxElut™ solid phase column all the commonly abused opioid drugs can be detected on a single thin-layer chromatography plate. Location of the spots is achieved by spraying the plate with iodoplatinate following acidification with dilute sulphuric acid. Sensitivity of the order of 1 mg/L is attained for most drugs.Keywords
This publication has 3 references indexed in Scilit:
- High performance liquid chromatographic analysis of basic drugs on silica columns using non-aqueous ionic eluentsJournal of Chromatography A, 1982
- Improved chromatographic techniques and their interpretation for the screening of urine from drug-dependent subjectsJournal of Chromatography A, 1971
- A Thin-Layer Chromatographic Screening Procedure for Detecting Drug AbuseAmerican Journal of Clinical Pathology, 1968