Temperature-Controlled Cooled-Tip Radiofrequency Ablation in Left Ventricular Myocardium Avoidance of Steam Pop During Ablation
Authors:
Open Access
- 1 January 2010
- journal article
- Published by International Heart Journal (Japanese Heart Journal) in International Heart Journal
- Vol. 51 (3) , 193-198
Abstract
Steam pop and intramural charring have been reported during cooled-tip radiofrequency catheter ablation (RFCA). We studied the feasibility of temperature-controlled cooled-tip RFCA in the canine heart. An internally cooled ablation catheter was inserted into the left ventricle. A custom-made radiofrequency (RF) generator capable of controlling the tip-temperature at the preset level by slow increases in the power was used. Temperature-controlled cooled-tip RF applications were performed at a target temperature of 40°C for 90 seconds. Acute study: Intramyocardial temperature was measured at the ablation site in 10 dogs by inserting a fluoroptic probe. Chronic study: Lesion depth and volume were measured in 5 dogs after 3 weeks of survival. In the acute study, no pop or abrupt impedance rise was observed. Maximum intramyocardial temperature was 72.4 ± 14.4°C at 2-4 mm above the endocardium. No coagulum formation, craters, or intramural charring were observed. Maximum lesion depth was 6.7 ± 1.5 mm, and lesion volume was 404 ± 219 mm3. In the chronic study, maximum lesion depth was 5.9 ± 1.1 mm, and lesion volume was 281 ± 210 mm3. Temperature controlled RFCA is feasible with a cooled-tip catheter and an RF generator that slowly increases the RF power until the preset catheter-tip temperature is reached.Keywords
This publication has 18 references indexed in Scilit:
- Cooled-Tip Ablation Results in Increased Radiofrequency Power Delivery and Lesion Size in the Canine Heart: Importance of Catheter-Tip Temperature Monitoring for Prevention of Popping and Impedance RiseJournal of Interventional Cardiac Electrophysiology, 2002
- Biophysics of Radiofrequency Ablation Using an Irrigated ElectrodeJournal of Interventional Cardiac Electrophysiology, 2001
- Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energyJACC, 2000
- Ablation of Ventricular Tachycardia with a Saline‐Cooled Radiofrequency Catheter:Journal of Cardiovascular Electrophysiology, 1999
- Temperature Guided Radiofrequency Catheter Ablation of Myocardium: Comparison of Catheter Tip and Tissue Temperatures In VitroPacing and Clinical Electrophysiology, 1997
- Radiofrequency Delivery Through a Cooled Catheter Tip Allows the Creation of Larger Endomyocardial Lesions in the Ovine HeartJournal of Cardiovascular Electrophysiology, 1995
- Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle PreparationCirculation, 1995
- Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation.Circulation, 1993
- Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium.Circulation, 1990
- Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free WallPacing and Clinical Electrophysiology, 1989