Atrial, Ventricular, or Both Cannulation Sites to Optimize Left Ventricular Assistance?
Authors:
- 1 May 2001
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 47 (3) , 261-265
Abstract
The efficiency of left ventricular assist devices (LVADs) depends on the capacity of the inflow cannula to drain blood into the pump. Left atrial (LA) and left ventricular (LV) sites were compared in an animal model mimicking different hemodynamic conditions. Three calves (56.3 ± 5.0 kg) were equipped with a Thoratec LVAD. A regular cardiopulmonary bypass (CPB) circuit was used as a right ventricular assist device (RVAD) (jugular vein/pulmonary artery), and preload conditions were adjusted by storage (or perfusion) of blood into (or from) the venous reservoir. LA and LV drainage, tested separately or simultaneously, was measured by its effect on the LVAD’s performance. The LVAD was used alone on a beating heart or together with the RVAD (biVAD) on a beating and on a fibrillating heart. Increasing the central venous pressure (CVP) highlighted the differences between the LA and LV cannulation sites when the LVAD was tested either alone or together with the RVAD (biVAD) on a beating heart. Drainage through the LA or the LV was similar when CVP was set at 8 mm Hg, and increasing CVP to 14 mm Hg allowed for better drainage through the LV cannula. In contrast, after induction of fibrillation to mimic extreme heart failure, the drainage was better through the LA cannula. Using both LA and LV cannulae simultaneously did not improve the LVAD output in any of the conditions tested. LV cannulation provides better blood drainage when used on a normal beating heart and, therefore, allows for increased LVAD performance. However, in severe heart failure, blood drainage through the LV cannula decreases and the LA cannulation site is superior.Keywords
This publication has 11 references indexed in Scilit:
- Single-center experience with the thoratec ventricular assist deviceThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Myocardial Gene Expression of Regulators of Myocyte Apoptosis and Myocyte Calcium Homeostasis During Hemodynamic Unloading by Ventricular Assist Devices in Patients With End-Stage Heart FailureCirculation, 1999
- Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist deviceThe Annals of Thoracic Surgery, 1999
- Clinical experience with 111 thoratec ventricular assist devicesThe Annals of Thoracic Surgery, 1999
- Regression of Cellular Hypertrophy After Left Ventricular Assist Device SupportCirculation, 1998
- Recovery from end-stage ischemic cardiomyopathy during long-term LVAD supportThe Annals of Thoracic Surgery, 1998
- Miniaturized implantable rotary blood pump in atrial–aortic position supports and unloads the failing heartCardiovascular Surgery, 1998
- Left Heart Bypass in the Pig with a Centrifugal Pump Using Cannulae Prepared for Percutaneous PlacementThe International Journal of Artificial Organs, 1998
- Left Atrial or Ventricular Cannulation Beyond 30 Days for a Thoratec Ventricular Assist DeviceASAIO Journal, 1995
- Reversal of Chronic Ventricular Dilation in Patients With End-Stage Cardiomyopathy by Prolonged Mechanical UnloadingCirculation, 1995