Variations of dose and electrode spacing for rat breast cancer electrochemical treatment
- 12 March 2001
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 22 (3) , 205-211
Abstract
Electrochemical treatment (EChT) with direct current delivered through implanted electrodes has been used for local control of solid tumors in humans. This study tested the hypothesis that rat breast cancer responses to EChT are dependent on electrode spacing and dose, and explored suitable parameters for treating breast cancers with EChT. Rat breast cancers were initiated by injecting 1 × 106 MTF‐7 cells to the right mammary gland fat pad of Fisher 344 female rats. The rats were randomly divided into designated experimental groups when the tumors grew to approximately 2 × 2 × 2 cm. One hundred and thirty rats were used for a survival study and 129 for a pathology study. A 4‐channel EChT machine was used to administer coulometric doses. The survival study indicated that local tumor control rate is less than 40% in the 40 coulomb (C) and 60 C groups and more than 70% in the 80 and 100 C groups. Sixty six rats died of primary tumors, including all 10 rats in the control group. Once a rat's primary tumor was controlled, no recurrence was found. The main reason for terminating the primary tumor‐free rats (51) was lymph node metastasis. Thirteen tumor‐free rats survived for more than 6 months. The pathology study showed a significant dose effect on EChT induced tumor necrosis. At 10, 20, 40, and 80 C, the fraction showing necrosis were 39.7, 52.3, 62, and 77.7%, respectively (P ≤ 0.001). Electrodes spacing was not an important factor within a given range. At 5, 10, and 15 mm spacing, the fraction showing the necrosis were 54.1, 60.4, and 59.2%, respectively (P = 0.552). The overlap rate of necroses was similar in the 5 and 10 mm groups (82.5 and 85%) and lower in the 15 mm group (65%). We conclude that the tumor responses to EChT, local control, survival rates, and necrosis percentages were significantly increased with increasing dose. The changes in electrode spacing (3, 5, and 10 mm) did not significantly affect the tumor responses to EChT within the same dose. For a diameter of 2.0–2.5 cm rat breast cancer, EChT should be applied with 5–10 mm spacing and a minimum dosage of 80 C. Bioelectromagnetics 22:205–211, 2001.Keywords
This publication has 11 references indexed in Scilit:
- Electrochemical treatment of human KB cells in vitroBioelectromagnetics, 1999
- Effects of direct current on dog liver: Possible mechanisms for tumor electrochemical treatmentBioelectromagnetics, 1997
- Electrochemical treatment of lung cancerBioelectromagnetics, 1997
- The effects of low-level direct current therapy on a preclinical mammary carcinoma: tumour regression and systemic biochemical sequelaeBritish Journal of Cancer, 1994
- Impact of Biologically closed electric circuits (BCEC) on structure and functionIntegrative Psychological and Behavioral Science, 1992
- Anti-tumor effect of electrotherapy alone or in combination with interleukin-2 in mice with sarcoma and melanoma tumorsAnti-Cancer Drugs, 1992
- Radiological evidence of response to electrochemical treatment of breast cancerClinical Radiology, 1991
- Electrochemical Treatment of Cancer. IIAmerican Journal of Clinical Oncology, 1990
- Fleischner lecture. Biokinetic impacts on structure and imaging of the lung: the concept of biologically closed electric circuitsAmerican Journal of Roentgenology, 1985
- Electrolysis and Surgery in Experimental Tumours in the RatActa Radiologica. Diagnosis, 1981