Color structured light system of chest wall motion measurement for respiratory volume evaluation
Open Access
- 1 January 2010
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (2) , 026013-026013-9
Abstract
We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.
Keywords
This publication has 16 references indexed in Scilit:
- 3-D shape measurement by composite pattern projection and hybrid processingOptics Express, 2007
- Application of long-period-grating sensors to respiratory plethysmographyJournal of Biomedical Optics, 2007
- Chest wall kinematics and respiratory muscle action in ankylosing spondylitis patientsEuropean Respiratory Journal, 2004
- Compartmental Analysis of Breathing in the Supine and Prone Positions by Optoelectronic PlethysmographyAnnals of Biomedical Engineering, 2001
- Fiber Optic Sensor for the Measurement of Respiratory Chest Circumference ChangesJournal of Biomedical Optics, 1999
- Three-dimensional optical analysis of chest wall motionJournal of Applied Physiology, 1994
- Use of a triaxial magnetometer for respiratory measurementsJournal of Applied Physiology, 1991
- Color-Encoded Structured Light for Rapid Active RangingIEEE Transactions on Pattern Analysis and Machine Intelligence, 1987
- Automated optical measurements of human torso surface movements during breathingJournal of Applied Physiology, 1986
- Measurement of the separate volume changes of rib cage and abdomen during breathingJournal of Applied Physiology, 1967