Wet and dry cup test with hygroscopic materials: what do we really measure?
Open Access
- 24 August 2024
- journal article
- Published by The International Society for Porous Media (InterPore) in InterPore Journal
- Vol. 1 (2) , ipj240824-4
Abstract
Wet and dry cup tests are widely used to characterize the vapor permeability (or the apparent vapor diffusion coefficient) of construction materials. From a theoretical approach, we examined the transport characteristics of such tests in detail. We precisely quantified the impact of the boundary conditions on the apparent diffusion coefficient and the time required to reach steady-state conditions, which is critical for accurate estimation of this coefficient. Finally, a major point concerns the physical meaning of the value measured through this type of test. For a homogeneous non-hygroscopic medium, the diffusion coefficient obtained represents the diffusion coefficient of vapor through the medium. For hygroscopic materials, where vapor diffusion, bound water diffusion, and sorption or desorption processes may be encountered, we demonstrate that the total water transport diffusion coefficient in the medium is strongly different from, yet proportional to, the apparent vapor diffusion coefficient. We validated and illustrated this analysis based on experiments with cellulose fiber stacks of different porosities and under different experimental conditions.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-11-LABX-022)
- H2020 European Research Council (PHYSBIOMAT - 101095764))
This publication has 26 references indexed in Scilit:
- Fast transport diffusion of bound water in cellulose fiber networkCellulose, 2023
- Accuracy of water vapor permeability of building materials reassessed by measuring cup's inner relative humidityBuilding and Environment, 2022
- Analysis of dynamic moisture movement within bio-based earth mortarsConstruction and Building Materials, 2021
- Performance of the bio-based materials2017
- Bio-aggregates Based Building Materials2017
- An investigation of moisture buffering performance of wood paneling at room level and its buffering effect on a test roomBuilding and Environment, 2012
- Experimental data set for validation of heat, air and moisture transport models of building envelopesBuilding and Environment, 2011
- The effect of combining a relative-humidity-sensitive ventilation system with the moisture-buffering capacity of materials on indoor climate and energy efficiency of buildingsBuilding and Environment, 2009
- Moisture buffering and effect of ventilation rate and volume rate of hygrothermal materials in a single room under steady state exterior conditionsBuilding and Environment, 2008
- Tools for performance simulation of heat, air and moisture conditions of whole buildingsBuilding Simulation, 2008