Initial experience of coaxial percutaneous liver biopsy with tract embolization using N -Butyl cyanoacrylate
- 5 June 2023
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 58 (11) , 1317-1320
Abstract
ObjectiveBleeding occurs after liver biopsy in up to 10.9% cases, and patients with impaired hemostasis or ascites are considered to have absolute or relative contraindications. N-butyl cyanoacrylate enables immediate hemostasis, even in lethal situations. Therefore, percutaneous liver biopsy combined with tract embolization using N-butyl cyanoacrylate is expected to enable safe biopsy, even in patients for whom conventional biopsy is contraindicated. Here we describe our initial experience with coaxial percutaneous biopsy with tract embolization using N-butyl cyanoacrylate.Materials and methodsEighty-six patients who underwent tract embolization using N-butyl cyanoacrylate between October 2014 and July 2020, including 21 patients who had absolute or relative contraindications for liver biopsy, were retrospectively analyzed. Tract embolization using N-butyl cyanoacrylate comprised two steps: (1) liver biopsy with a biopsy needle inserted via a coaxial introducer needle and (2) embolization of the puncture route by injecting N-butyl cyanoacrylate via the coaxial needle.ResultsNo complications occurred in any patient. The mean number of biopsies per patient was 3.30 (range, 1-7). Histologically adequate samples were acquired in all cases, and pathological diagnoses were obtained. The mean time required for tract embolization was 52.8 s (range, 6-132 s). The mean peak skin dose was 9.97 mGy (range, 2-68 mGy), which is far below the 3-Gy threshold dose for temporary erythema.ConclusionsThis proposed technique may be a promising and straightforward alternative to improve the management of patients with severe liver disease by allowing safer biopsy, including patients for whom conventional liver biopsy is contraindicated.Keywords
This publication has 15 references indexed in Scilit:
- Guidelines for the use of NBCA in vascular embolization devised by the Committee of Practice Guidelines of the Japanese Society of Interventional Radiology (CGJSIR), 2012 editionJapanese Journal of Radiology, 2014
- Undiluted N-butyl cyanoacrylate is safe and effective for gastric variceal bleedingGastrointestinal Endoscopy, 2010
- A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an “In-House” Protocol for Selecting the Procedure of ChoiceCardioVascular and Interventional Radiology, 2009
- Liver biopsy†Hepatology, 2009
- Plugged-Percutaneous Liver Biopsy in Patients with Impaired Coagulation and AscitesPathophysiology of Haemostasis and Thrombosis, 2002
- Autologous Blood Clot Seal to Prevent Pneumothorax at CT-guided Lung BiopsyRadiology, 2000
- Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85Annals of the ICRP, 2000
- Percutaneous transhepatic liver biopsy with tract embolization.Radiology, 1996
- Fibrin sealant as a plug for the post liver biopsy needle trackClinical Radiology, 1989
- Percutaneous liver biopsy and track embolization with steel coils.Radiology, 1988