Cost-effectiveness of an insertable cardiac monitor in a high-risk population in the UK
Open Access
- 20 June 2019
- journal article
- research article
- Published by BMJ in Open Heart
- Vol. 6 (1) , e001037
Abstract
Objective: To evaluate the cost-effectiveness of insertable cardiac monitors (ICMs) compared with standard of care (SoC) for detecting atrial fibrillation (AF) in patients at high risk of stroke (CHADS2 >2), using a UK National Health Service (NHS) perspective. Methods: Using patient characteristics and clinical data from the REVEAL AF trial, a Markov model assessed the cost-effectiveness of detecting AF with an ICM compared with SoC. Costs and benefits were extrapolated across modelled patient lifetime. Ischaemic and haemorrhagic strokes, intracranial and extracranial haemorrhages and minor bleeds were modelled. Diagnostic and device costs were included, plus costs of treating stroke and bleeding events and costs of oral anticoagulants (OACs). Costs and health outcomes, measured as quality-adjusted life years (QALYs), were discounted at 3.5% per annum. One-way deterministic and probabilistic sensitivity analyses (PSA) were undertaken. Results: The total per-patient cost for ICM was £13 360 versus £11 936 for SoC (namely, annual 24 hours Holter monitoring). ICMs generated a total of 6.50 QALYs versus 6.30 for SoC. The incremental cost-effectiveness ratio (ICER) was £7140/QALY gained, below the £20 000/QALY acceptability threshold. ICMs were cost-effective in 77.4% of PSA simulations. The number of ICMs needed to prevent one stroke was 21 and to cause a major bleed was 37. ICERs were sensitive to assumed proportions of patients initiating or discontinuing OAC after AF diagnosis, type of OAC used and how intense the traditional monitoring was assumed to be under SoC. Conclusions: The use of ICMs to identify AF in a high-risk population is cost-effective for the UK NHS.Keywords
Funding Information
- Medtronic PLC
This publication has 27 references indexed in Scilit:
- Subclinical Atrial Fibrillation and the Risk of StrokeNew England Journal of Medicine, 2012
- Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplainedEP Europace, 2011
- The Relationship Between Daily Atrial Tachyarrhythmia Burden From Implantable Device Diagnostics and Stroke RiskCirculation: Arrhythmia and Electrophysiology, 2009
- Cost-effectiveness of warfarin: Trial versus “real-world” stroke prevention in atrial fibrillationAmerican Heart Journal, 2009
- New Insights into Long‐Term Follow‐Up of Atrial Fibrillation Ablation: Full Disclosure by an Implantable Pacemaker DeviceJournal of Cardiovascular Electrophysiology, 2007
- Clinical Implications of Various Follow Up Strategies After Catheter Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 2007
- Relationship between atrial tachyarrhythmias and symptomsHeart Rhythm, 2005
- Selecting Patients With Atrial Fibrillation for AnticoagulationCirculation, 2004
- Risk Factors for Intracerebral Hemorrhage in the General PopulationStroke, 2003
- Atrial fibrillation as an independent risk factor for stroke: the Framingham Study.Stroke, 1991