Primary Stability Comparison Using Piezoelectric or Conventional Implant Site Preparation Systems in Cancellous Bone
Authors:
- Shweta A. GandhiSGShweta A. Gandhi
- Justin A. BakerJBJustin A. Baker
- Latifa BairamLBLatifa Bairam
- Hyeong-Il KimHKHyeong-Il Kim
- Elaine L. DavisEDElaine L. Davis
- Sebastiano AndreanaSASebastiano Andreana
- 1 February 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 23 (1) , 79-84
Abstract
This study compares implant primary stability achieved in cancellous bone after placement in piezoelectric prepared sites versus conventionally drilled sites. Four bovine ribs were randomly assigned and placed in a water bath at 36.5 °C. Five sites per rib (total n = 20 sites) were prepared using piezoelectric system (test) or conventional drills (control) with twenty 10 × 3.6-mm Implantium implants placed. Using Osstell Mentor quantitative analysis, 5 resonance frequency analysis [implant stability quotient {ISQ}] values per implant were recorded at 5 locations for a total of 100 measurements. Independent t test analysis indicated significant difference in primary stabilities between groups: t (17) = 2.637, P = 0.17, with equal variance assumption satisfied (P = 0.196). Examination of means indicated a higher mean ISQ for piezoelectric than for conventional: 58.9 (+8.55) versus 49.2 (+7.33), respectively. Analysis of variance indicated a significant difference in mean ISQ value by rib. Tukey test indicated significantly higher ISQ values for rib A (test) than ribs B, C (control), and D (test). Implant site preparation using the piezoelectric system gives higher implant primary stability in cancellous bone. However, variations in quality across bones may have affected the results.Keywords
This publication has 22 references indexed in Scilit:
- A comparative study on the accuracy of the devices for measuring the implant stabilityThe Journal of Advanced Prosthodontics, 2009
- Piezoelectric surgery: Twenty years of useBritish Journal of Oral and Maxillofacial Surgery, 2008
- Ultrasonic osteotomy as a new technique in craniomaxillofacial surgeryInternational Journal of Oral and Maxillofacial Surgery, 2007
- Cortical Bone Thickness in Dentate and Edentulous Human CadaversJournal of Periodontology, 2007
- Cytokines and Growth Factors Involved in the Osseointegration of Oral Titanium Implants Positioned Using Piezoelectric Bone Surgery Versus a Drill Technique: A Pilot Study in MinipigsJournal of Periodontology, 2007
- Piezoelectric osteotomy in hand surgery: first experiences with a new techniqueBMC Musculoskeletal Disorders, 2006
- Predicting osseointegration by means of implant primary stabilityClinical Oral Implants Research, 2004
- Biological factors contributing to failures of osseointegrated oral implants, (II). EtiopathogenesisEuropean Journal of Oral Sciences, 1998
- Anatomic Site Evaluation of Edentulous Maxillae for Dental Implant PlacementJournal of Prosthodontics, 1995
- Reduction of the compact and cancellous bone substances of the edentulous mandible caused by resorptionOral Surgery, Oral Medicine, Oral Pathology, 1992