Point‐of‐care measurement of fetal blood lactate – Time to trust a new device
- 31 July 2017
- journal article
- research article
- Published by Wiley in Australian and New Zealand Journal of Obstetrics and Gynaecology
- Vol. 58 (1) , 72-78
Abstract
Background: Point‐of‐care lactate devices are used worldwide for intrapartum decision making. Current practice is often based on Lactate Pro (Arkray) but its imminent product discontinuation necessitates determination of an optimal replacement device.Aims: To evaluate the performance of Lactate Pro and two other point‐of‐care devices, Lactate Pro 2 (Arkray) and StatStrip (Nova Biomedical), and to derive scalp lactate cut‐offs equivalent to the current intervention trigger of >4.8 mmol/L.Materials and methods: Paired umbilical cord arterial and venous blood samples from 109 births were tested on the three point‐of‐care products (two devices each), cross‐compared with the reference method blood gas analyser.Results: All brands deviate from the blood gas analyser, with Lactate Pro and StatStrip results consistently lower and Lactate Pro 2 consistently higher. Standard deviation from the blood gas analyser was smallest for StatStrip (0.78 mmol/L, cord artery), and largest for Lactate Pro 2 (1.03 mmol/L, cord artery). Within‐brand variation exists and is similar for all brands (mean absolute difference on cord artery 0.23–0.30 mmol/L). Equivalent values to the 4.8 mmol/L intervention threshold based on Lactate Pro are 4.9–5.0 mmol/L for StatStrip and 5.3–5.9 mmol/L for Lactate Pro 2, calculated by receiver‐operating characteristic analysis.Conclusions: StatStrip appears superior to Lactate Pro 2 to replace the original Lactate Pro. Using StatStrip, the 4.8 mmol/L intervention threshold equivalent was 4.9–5.0 mmol/L. The variation in accuracy of point‐of‐care lactate devices may exceed the small increments (eg 4.8 mmol/L) that guide obstetric decisions.Keywords
This publication has 23 references indexed in Scilit:
- FIGO consensus guidelines on intrapartum fetal monitoring: Adjunctive technologiesInternational Journal of Gynecology & Obstetrics, 2015
- Comparing fetal scalp lactate and umbilical cord arterial blood gas valuesAustralian and New Zealand Journal of Obstetrics and Gynaecology, 2014
- Validation of a point-of-care (POC) lactate testing device for fetal scalp blood sampling during labor: clinical considerations, practicalities and realitiesClinical Chemistry and Laboratory Medicine (CCLM), 2014
- Lactate study using umbilical cord blood: Agreement between Lactate Pro hand-held devices with blood gas analyser and evaluation of lactate stability over timeAustralian and New Zealand Journal of Obstetrics and Gynaecology, 2013
- Suitability of POC lactate methods for fetal and perinatal lactate testing: considerations for accuracy, specificity and decision making criteriaClinical Chemistry and Laboratory Medicine (CCLM), 2012
- Fetal Scalp Lactate Microsampling for Non-Reassuring Fetal Status during Labor: A Prospective Observational StudyFetal Diagnosis and Therapy, 2009
- Comparison and validation of point of care lactate meters as a replacement for fetal pH measurementClinical Biochemistry, 2008
- Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trialBMJ, 2008
- Effect of Perinatal Asphyxia on Systemic and Intracerebral pH and Glycolysis Metabolism in the RatExperimental Neurology, 1997
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986