Considerations upon applying tripodic coupling in artificial hip joint
Open Access
- 1 August 2016
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 147 (1) , 012074
Abstract
The employment of tripodic joint allows creation of homokinetical transmissions and thus it is expected that at the use of such a transmission for a dynamical system with smooth enough inputs, the outputs should maintain the same characteristics. The present paper presents a comparison between the effect of using a spherical joint in spatial mechanisms - the classical solution for hip joint implant, and the effect of replacing such prosthesis with a tripodic coupling.Keywords
This publication has 9 references indexed in Scilit:
- CONSIDERATIONS UPON A NEW TRIPOD JOINT SOLUTIONMechanics, 2013
- Total Hip Arthroplasty – over 100 years of operative historyOrthopedic Reviews, 2011
- Kinematic investigation of tripod sliding universal joints based on coordinate transformationMultibody System Dynamics, 2009
- A dynamic model of jaw and hyoid biomechanics during chewingJournal of Biomechanics, 2008
- Freedom in Machinery2007
- Dynamics of the Human Masticatory SystemCritical Reviews in Oral Biology & Medicine, 2002
- Kinematics of Tripode Transmissions. A New ApproachMultibody System Dynamics, 1999
- Kinematic and Dynamic Analyses of the Tripode JointMultibody System Dynamics, 1998
- Hip Biomechanics1993