Simultaneous Determination of Ozone and Carbonyls Using trans-1,2-Bis(4-pyridyl)ethylene as an Ozone Scrubber for 2,4-Dinitrophenylhydrazine-Impregnated Silica Cartridge
- 15 March 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (9) , 3285-3290
Abstract
A new method for the simultaneous determination of ozone and carbonyls in air using a two-bed cartridge system has been developed. Each bed consists of reagent-impregnated silica particles. The first contains trans-1,2-bis-(4-pyridyl) ethylene (BPE) while the second contains 2,4-dinitrophenylhydrazine (DNPH). Air samples are drawn through the cartridge first through the BPE and then through the DNPH. Ozone in the air sample is trapped in the first bed by the BPE-coated silica particles and produce pyridine-4-aldehyde. Airborne carbonyls pass unimpeded thorough the BPE and are trapped in the second bed by the DNPH-coated silica particles. They produce carbonyl 2,4-DNPhydrazones. DNPH and carbonyl 2,4-DNPhydrazones are not influenced by ozone because of effective trapping by the BPE. Extraction is performed in the direction reverse to air sampling. When solvent is eluted through the BEP/DNPH cartridge, excess DNPH is washed into the BPE bed where it reacted with pyridine-4-aldehyde and forms the corresponding hydrazone derivative. All of the hydrazones derived from airborne carbonyls and pyridine-4-aldehyde (derived from ozone) are completely separated and measured using high-performance liquid chromatography. An Ascentis RP-Amide column is used, and the mobile phase is 40% aqueous acetonitrile containing 2 mmol/L ammonium acetate. The use of a BPE/DNPH cartridge has made possible the simultaneous determination of ozone and carbonyls. A separate ozone scrubber is not necessary with the BPE/DNPH cartridge because the BPE portion of the sampler serves this function.Keywords
This publication has 20 references indexed in Scilit:
- Acid-catalyzed isomerization and decomposition of ketone-2,4-dinitrophenylhydrazonesAnalytica Chimica Acta, 2007
- Radial diffusive sampler for the determination of 8-h ambient ozone concentrationsEnvironmental Pollution, 2007
- Reactions between ozone and building products: Impact on primary and secondary emissionsAtmospheric Environment, 2007
- Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozoneAtmospheric Environment, 2006
- Ozone Measurement with Passive Samplers: Validation and Use for Ozone Pollution Assessment in Montpellier, FranceEnvironmental Science & Technology, 1998
- Evaluation of the Performance of DNPH-Coated Silica Gel and C18 Cartridges in the Measurement of Formaldehyde in the Presence and Absence of OzoneEnvironmental Science & Technology, 1998
- Evaluation of ozone and water vapor interferences in the derivatization of atmospheric aldehydes with dansylhydrazineEnvironmental Science & Technology, 1993
- Measurement of ambient ozone using a nitrite-coated filterAnalytical Chemistry, 1993
- A passive sampler for formaldehyde in air using 2,4-dinitrophenylhydrazine-coated glass fiber filtersEnvironmental Science & Technology, 1986
- Guidelines for data acquisition and data quality evaluation in environmental chemistryAnalytical Chemistry, 1980