An evaluation of organ dose modulation on a GE optima CT660‐computed tomography scanner
Open Access
- 8 May 2016
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (3) , 380-391
Abstract
Organ Dose Modulation or ODM (GE Healthcare, Milwaukee, WI) was evaluated to characterize changes in , image noise, effective dose, and organ dose saving to patients. Three separate investigations were completed: a tube current modulation phantom was scanned with and without ODM, a phantom was scanned with ODM, and Monte Carlo simulations were performed. ODM was found to reduce the by approximately 20% whilst increasing the noise by approximately 14%. This was reflected in the dose distribution, where the anterior peripheral dose was reduced by approximately 40% whilst the identical posterior dose remained largely unaffected. Enabling ODM for the entire scan would reduce the effective dose by approximately 24%; however, this saving reduces to 5% if the images are matched for . These savings mostly originated from reductions in dose to the stomach, breasts, colon, bladder, and liver. ODM has the effect of a global reduction in with an associated increase in image noise. The benefit of ODM was found to be reduced when the dose-saving contribution from the reduced was removed. Given that there is a higher contribution to effective dose throughout the body from the anterior projections, consideration should be given to applying ODM throughout. PACS number(s): 87.10.Rt, 87.53.Bn, 87.57.C-, 87.57.Q-
Keywords
This publication has 7 references indexed in Scilit:
- Organ-based Tube Current Modulation: Are Women’s Breasts Positioned in the Reduced-Dose Zone?Radiology, 2015
- The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imagingPediatric Radiology, 2013
- An evaluation of in-plane shields during thoracic CTRadiation Protection Dosimetry, 2013
- A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiologyRadiation Protection Dosimetry, 2012
- Organ-Based Dose Current Modulation and Thyroid Shields: Techniques of Radiation Dose Reduction for Neck CTAmerican Journal of Roentgenology, 2012
- Assessment of an organ‐based tube current modulation in thoracic computed tomographyJournal of Applied Clinical Medical Physics, 2012
- Practical dosimetry methods for the determination of effective skin and breast dose for a modern CT system, incorporating partial irradiation and prospective cardiac gatingBritish Journal of Radiology, 2012