DDI Pacing: Indications, Expectations, and Follow‐Up
Authors:
- 1 March 1994
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (3) , 274-279
Abstract
The DDI mode of pacing that permits noncompetitive atrioventricular sequential bradycardia support was chosen in 65 of 480 (14%) patients selected for dual chamber pacing between February 1985 and March 1990. All patients were implanted with Pacesetter 283 or 285 pulse generators and programmed to DDI. The indications for pacing were sick sinus syndrome (n = 52), combined sinus node dysfunction and AV block (n = 13). Forty-two of these patients had a history of paroxysmal atrial arrhythmias. All patients received passive fixation atrial and ventricular leads. Follow-up thereafter was performed predischarge, and at 6 weeks, 3 and 6 months after discharge. The duration of follow-up ranged from 1-61 months (mean 31 months). Fifty-four of 65 (83%) patients chosen for DDI remain programmed in the DDI mode. Three patients were reprogrammed to VVI and eight to DDD. During the course of follow-up, six patients presented with effective VVI pacing with consistent ventriculoatrial conduction that was appropriately sensed by the atrial circuit with atrial output inhibition. A further four patients presented with "functional undersensing" due to ventricular blanking period (VBP) characteristics in these pulse generators and in this mode. Functional undersensing was eliminated in all but one patient by reprogramming the VBP to 13 msec with no subsequent episodes of provoked crosstalk inhibition. Effective VVI pacing was observed in patients with AV block during times of sinus acceleration.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 18 references indexed in Scilit:
- DDI Pacing in the Bradycardia-Tachycardia SyndromePacing and Clinical Electrophysiology, 1990
- Pacemaker syndrome due to retrograde conduction in a DDI pacemakerAmerican Heart Journal, 1988
- The DDI Mode of Cardiac PacingPacing and Clinical Electrophysiology, 1987
- What Is the Most Appropriate Stimulation Mode in Patients with Sinus Node Dysfunction?Pacing and Clinical Electrophysiology, 1986
- A Case of Ventricular Undersensing in the DDI Mode: Cause and CorrectionPacing and Clinical Electrophysiology, 1986
- Inappropriate Ventricular Blanking in a DDI PacemakerPacing and Clinical Electrophysiology, 1986
- Tracking of Atrial Flutter During DDD Pacing: Another Form of Pacemaker‐Mediated TachycardiaPacing and Clinical Electrophysiology, 1984
- Characterization of Pacemaker Arrhythmias Due to Normally Functioning AV Demand (DVI) Pulse GeneratorsPacing and Clinical Electrophysiology, 1980
- Physiologic PacingPacing and Clinical Electrophysiology, 1980
- Physiological Cardiac PacingPacing and Clinical Electrophysiology, 1980