Self‐navigated multishot echo‐planar pulse sequence for high‐resolution diffusion‐weighted imaging
Open Access
- 19 May 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (6) , 1474-1478
Abstract
Single‐shot techniques have preferentially been adopted for diffusion‐weighted imaging due to their reduced sensitivity to bulk motion. However, the limited spatial resolution achievable results in orientational signal averaging within voxels containing a distribution of fibers. This leads to impaired performance of tracking algorithms. To combat partial volume effects, high‐resolution multishot techniques can be used but, being more sensitive to motion, require phase correction to obtain artifact‐free images. While separately acquiring 2D navigator echoes is an effective approach, it is not very efficient as the navigators do not contribute signal to the final image. Here a self‐navigated interleaved echo planar imaging (EPI) sequence based on EPI with keyhole (EPIK) is proposed. The refocusing reconstruction method is successfully adapted to EPIK and compared to the standard linear approach. The resultant improvement in resolution is shown to lead to a significant increase in anisotropy in fiber‐branching areas and can potentially offer a superior ability to detect fine tract splits. Magn Reson Med 53:1474–1478, 2005.Keywords
This publication has 18 references indexed in Scilit:
- Characterization and propagation of uncertainty in diffusion‐weighted MR imagingMagnetic Resonance in Medicine, 2003
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRIMagnetic Resonance in Medicine, 2002
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Fiber tracking: principles and strategies – a technical reviewNMR in Biomedicine, 2002
- Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain ImagesNeuroImage, 2002
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- Toward a quantitative assessment of diffusion anisotropyMagnetic Resonance in Medicine, 1996
- Theoretical and experimental evaluation of phase‐dispersion effects caused by brain motion in diffusion and perfusion MR imagingJournal of Magnetic Resonance Imaging, 1996
- Analysis and correction of motion artifacts in diffusion weighted imagingMagnetic Resonance in Medicine, 1994