Accuracy of Portable Ultrasound Measurement of the Bladder Volume Using the Manual Fanning Scan and Traditional Motorized Scan Methods
Open Access
- 31 December 2025
- journal article
- Published by Korean Continence Society in International Neurourology Journal
- Vol. 29 (4) , 296-301
Abstract
Purpose: To compare the accuracy of portable ultrasound bladder scanner (PUBS) for measuring bladder volume (BV) using manual fanning scan (MFS) and traditional motorized scan (TMS) methods.Methods: Patients with lower urinary tract symptoms who underwent a urodynamic study at the urology outpatient clinic from October to December 2024 were prospectively enrolled. BV was measured using TMS-type (TMS-BV) and MFS-type (MFS-BV) PUBS prior to free uroflowmetry. True BV (T-BV) was defined as the sum of the voided volume and the postvoid residual volume drained through the urethral catheter after voiding. TMS-BV and MFS-BV were compared and analyzed against T-BV.Results: Data from 39 patients (30 males and 9 females; mean age, 65.3±14.8 years) were analyzed. TMS-BV (230.9±157.9 mL) and MFS-BV (222.6±154.2 mL) did not differ significantly from T-BV (230.6±156.6 mL) (P>0.05). Comparison of the percentage of difference in volume between TMS-BV and MFS-BV across 100-mL BV ranges revealed no significant difference (P>0.05). The mean difference between TMS-BV and T-BV (0.2±50.2) did not differ significantly from the mean difference between MFS-BV and T-BV (-8.0±69.1) (P>0.05). The correlation between TMS-BV and T-BV (R2=0.90) was stronger than that between MFS-BV and T-BV (R2=0.81).Conclusions: The correlation between MFS-type PUBS and T-BV was lower than that between TMS-type PUBS and T-BV. However, the measurement accuracy of BV was similar using both methods.Keywords
This publication has 15 references indexed in Scilit:
- Weakly supervised learning‐based 3D bladder reconstruction from 2D ultrasound images for bladder volume measurementMedical Physics, 2023
- Can portable ultrasound bladder scanner be applied to young children less than three years old?Journal of Pediatric Urology, 2022
- Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurementInternational Urogynecology Journal, 2016
- The use of portable ultrasound devices in low‐ and middle‐income countries: a systematic review of the literatureTropical Medicine & International Health, 2016
- Measurement of post‐void residual urineNeurourology and Urodynamics, 2014
- Accuracy of post‐void residual urine volume measurement using a portable ultrasound bladder scanner with real‐time pre‐scan imagingNeurourology and Urodynamics, 2011
- Bladder Volume Determination: Two-dimensional Versus Three-dimensional Transvaginal UltrasoundTaiwanese Journal of Obstetrics and Gynecology, 2009
- Portable Ultrasonography and Bladder Volume Accuracy—A Comparative Study Using Three-Dimensional UltrasonographyUrology, 2008
- Accuracy of bladder volume determinations by ultrasonography: are they accurate over entire bladder volume range?Urology, 2003
- Ultrasonic Studies of the BladderJournal of Urology, 1967