Semiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation
Open Access
- 1 January 2014
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2014, 1-8
Abstract
A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.
Keywords
Funding Information
- Swiss National Science Foundation
- European Commission
This publication has 25 references indexed in Scilit:
- Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human CochleaOtology & Neurotology, 2010
- Optimal Cochlear Implant Insertion VectorsOtology & Neurotology, 2010
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Scala Tympani Cochleostomy II: Topography and HistologyThe Laryngoscope, 2007
- Navigationsgeführte minimal-invasive Cochlea-Implantation - Untersuchungen am humanen FelsenbeinLaryngo-Rhino-Otologie, 2007
- Anatomy of the Round Window and Hook Region of the Cochlea With Implications for Cochlear Implantation and Other Endocochlear Surgical ProceduresOtology & Neurotology, 2007
- Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in AdultsEar & Hearing, 2007
- Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approachActa Oto-Laryngologica, 2007
- Preservation of Hearing in Cochlear Implant Surgery: Advantages of Combined Electrical and Acoustical Speech ProcessingThe Laryngoscope, 2005
- Preservation of Basal Inner Ear Structures in Cochlear ImplantationORL, 2004