Abstract
In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot-through in voltage source converter during a switching period, a dead time is added either in the hardware drivers of the IGBTs or implemented in the software Pulse-Width Modulation (PWM) scheme. Both methods will lead to a degradation of the injected current power quality. Thus, the harmonics induced by the dead time have to be compensated in order to achieve a satisfactory current as required by the standards. In this paper, a repetitive controller has been introduced to eliminate the dead-time effect in grid-connected PWM converters. The repetitive controller has been plugged into a proportional resonant based fundamental controller. Compared with the traditional dead-time compensation solutions, the repetitive controller can effectively compensate the dead-time harmonics as well as other low-order distortions, and also it is a simple method without hardware modifications. Experimental results are demonstrating the advantages of the proposed dead-time effect mitigation method compared to the resonant based harmonic compensator.Keywords
This publication has 26 references indexed in Scilit:
- Dead-Time Compensation Method Based on Current Ripple EstimationIEEE Transactions on Power Electronics, 2014
- A Simple and Direct Dead-Time Effect Compensation Scheme in PWM-VSIIEEE Transactions on Industry Applications, 2014
- On the Compensation of Dead Time and Zero-Current Crossing for a PWM-Inverter-Controlled AC Servo DriveIEEE Transactions on Industrial Electronics, 2004
- Power electronics as efficient interface in dispersed power generation systemsIEEE Transactions on Power Electronics, 2004
- Dead-Time Issues in Predictive Current ControlIEEE Transactions on Industry Applications, 2004
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002
- A two-degrees-of-freedom current control scheme for deadtime compensationIEEE Transactions on Industrial Electronics, 2000
- On-line dead-time compensation technique for open-loop PWM-VSI drivesIEEE Transactions on Power Electronics, 1999
- Improved modulation techniques for PWM-VSI drivesIEEE Transactions on Industrial Electronics, 1997
- The internal model principle for linear multivariable regulatorsApplied Mathematics & Optimization, 1975