The Effect of a PEEK Material-Based External Fixator in the Treatment of Distal Radius Fractures with Non-Transarticular External Fixation
Open Access
- 1 February 2021
- journal article
- research article
- Published by Wiley in Orthopaedic Surgery
- Vol. 13 (1) , 90-97
Abstract
Objective To explore the effect of a PEEK material-based external fixator in the treatment of distal radius fractures with non-transarticular external fixation. Methods There were 48 patients in this prospective comparative study. They were divided into two groups according to the materials used: the PEEK group and the titanium group. Wrist dorsiflexion, palmar flexion, pronation, supination, radial deviation, ulnar deviation, grip strength of the palm on the affected side, kneading force, Visual Analogue Scale/Score (VAS), Disabilities of the Arm, Shoulder, and Hand (DASH) score, operation time, frequency of fluoroscopy procedures, and X-ray results were compared between the two groups. Functional recovery was evaluated at the last follow-up according to the wrist joint evaluation criteria. Results The baseline data were comparable between the two groups, and no significant differences were found in age, sex, fracture types (P > 0.05). There was no significant difference between the two groups in the results of DASH, grip strength, and recovery of pinch force and wrist function (dorsiflexion, clavicle, ulnar deviation, deviation, pronation, and supination) (P > 0.05). Normal limb function was achieved in the two groups of patients at an average of 6 weeks after surgery, and there was no significant difference in X-ray examination radial height (10.60 +/- 1.59 vs 11.00 +/- 1.53, P = 0.687), radial inclination (1.11 +/- 0.24 vs 1.12 +/- 0.24, P = 0.798), volar tilt (10.33 +/- 2.13 vs 10.00 +/- 2.08, P = 0.660), ulnar variance (20.87 +/- 3.00 vs 20.38 +/- 3.04, P = 0.748), and step-off persistence (1.73 +/- 0.69 vs 1.68 +/- 0.72, P = 0.425) between the two groups (P > 0.05). However, the operation time (54.80 +/- 12.20 vs 85.23 +/- 15.14, P = 0.033) and number of fluoroscopy procedures (36.93 +/- 6.89 vs 64.77 +/- 9.74, P = 0.000) in the PEEK group were significantly reduced compared with those in the titanium group. Conclusion Compared with the traditional titanium external fixator, the PEEK composite external fixator has advantages, such as a shorter operation time and fewer fluoroscopy procedures when used to treat different types of distal radius fracture.Keywords
This publication has 31 references indexed in Scilit:
- The Effects of Pronator Quadratus Repair on Outcomes After Volar Plating of Distal Radius FracturesJournal of Orthopaedic Trauma, 2013
- A Systematic Review of Outcomes and Complications of Treating Unstable Distal Radius Fractures in the ElderlyThe Journal of Hand Surgery, 2011
- Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixatorInjury, 2010
- PEEK cages as a potential alternative in the treatment of cervical spondylodiscitis: a preliminary report on a patient seriesEuropean Spine Journal, 2010
- Biomechanical Characteristics of Nonbridging External Fixators for Distal Radius FracturesThe Journal of Hand Surgery, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Fractures of the Distal Radius Treated With a Nonbridging External Fixation Technique Using Multiplanar K-WiresThe Journal of Hand Surgery, 2005
- Biomechanics and Biology of External Fixation of Distal Radius FracturesHand Clinics, 2005
- Rehabilitation of Distal Radius Fractures: A Biomechanical GuideHand Clinics, 2005
- Assessment of instability factors in adult distal radius fracturesThe Journal of Hand Surgery, 2004