Influence of Mechanical Ventilation Systems and Human Occupancy on Time-Resolved Source Rates of Volatile Skin Oil Ozonolysis Products in a LEED-Certified Office Building
- 1 December 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 55 (24) , 16477-16488
Abstract
Building mechanical ventilation systems are a major driver of indoor air chemistry as their design and operation influences indoor ozone (O3) concentrations, the dilution and transport of indoor-generated volatile organic compounds (VOCs), and indoor environmental conditions. Real-time VOC and O3 measurements were integrated with a building sensing platform to evaluate the influence of mechanical ventilation modes and human occupancy on the dynamics of skin oil ozonolysis products (SOOPs) in an office in a LEED-certified building during the winter. The ventilation system operated under variable recirculation ratios (RRs) from RR = 0 (100% outdoor air) to RR = 1 (100% recirculation air). Time-resolved source rates for 6-methyl-5-hepten-2-one (6-MHO), 4-oxopentanal (4-OPA), and decanal were highly dynamic and changed throughout the day with RR and occupancy. Total SOOP source rates during high-occupancy periods (10:00–18:00) varied from 2500–3000 μg h–1 when RR = 0.1 to 6300–6700 μg h–1 when RR = 1. Source rates for gas-phase reactions, outdoor air, and occupant-associated emissions generally decreased with increasing RR. The recirculation air source rate increased with RR and typically became the dominant source for RR > 0.5. SOOP emissions from surface reservoirs were also a prominent source, contributing 10–50% to total source rates. Elevated per person SOOP emission factors were observed, potentially due to multiple layers of soiled clothing worn during winter.Keywords
Funding Information
- Alfred P. Sloan Foundation (G-2018-11061)
- National Science Foundation (CBET-1805804)
This publication has 78 references indexed in Scilit:
- Unexpectedly high indoor hydroxyl radical concentrations associated with nitrous acidProceedings of the National Academy of Sciences of the United States of America, 2013
- Irritancy and Allergic Responses Induced by Exposure to the Indoor Air Chemical 4-OxopentanalToxicological Sciences, 2012
- Changing laundry habits in NorwayInternational Journal of Consumer Studies, 2012
- Reactions of ozone with human skin lipids: Sources of carbonyls, dicarbonyls, and hydroxycarbonyls in indoor airProceedings of the National Academy of Sciences of the United States of America, 2010
- Evaluation of Dicarbonyls Generated in a Simulated Indoor Air Environment Using an In Vitro Exposure SystemToxicological Sciences, 2010
- Ozone consumption and volatile byproduct formation from surface reactions with aircraft cabin materials and clothing fabricsAtmospheric Environment, 2008
- Sorption of organic gases in a furnished roomAtmospheric Environment, 2004
- Comedogenicity of squalene monohydroperoxide in the skin after topical application.The Journal of Toxicological Sciences, 2000
- Evaluation of Activated Carbon Filters for Removal of Ozone at the PPB LevelAIHA Journal, 1999
- Measurements of the Hydroxyl Radical in a Manipulated but Realistic Indoor EnvironmentEnvironmental Science & Technology, 1997