Pseudomonas aeruginosa infections due to electronic faucets in a neonatal intensive care unit
- 16 November 2011
- journal article
- Published by Wiley in Journal of Paediatrics and Child Health
- Vol. 48 (5) , 430-434
Abstract
Aim: To evaluate the role of electronic faucets in a newborn intensive care unit during a Pseudomonas aeruginosa outbreak.Methods: After three patients had P. aeruginosa bacteremia, environmental cultures including those from patient rooms, incubator, ventilators, total parenteral nutrition solutions, disinfection solutions, electronic and hand‐operated faucet filters/water samples after removing filters and staff hands were taken.Results: Only filters of electronic faucets and water samples after removing filters and one liquid hand soap showed P. aeruginosa (3–7 × 106 cfu/mL). We have removed the electronic faucets and new elbow‐operated faucets were installed. Pulsed‐field gel electrophoresis analysis of outbreak‐blood culture isolates from two patients and isolates from electronic water faucets/one liquid hand soap indicated the presence of 90.7% genetically related subtype, probably from the same clone. Water cultures from new faucets were all clean after installation and after 7 months.Conclusion: We suggest that electronic faucets may be considered a potential risk for P. aeruginosa in hospitals, especially in high‐risk units.Keywords
This publication has 24 references indexed in Scilit:
- Contaminated feeding bottles: The source of an outbreak of Pseudomonas aeruginosa infections in a neonatal intensive care unitAmerican Journal of Infection Control, 2009
- Should electronic faucets be used in intensive care and hematology units?Intensive Care Medicine, 2005
- Non-touch fittings in hospitals: a procedure to eradicate Pseudomonas aeruginosa contaminationJournal of Hospital Infection, 2005
- Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp.Journal of Hospital Infection, 2003
- Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp.Journal of Hospital Infection, 2001
- Prospective study of nosocomial colonization and infection due to Pseudomonas aeruginosa in mechanically ventilated patientsIntensive Care Medicine, 2001
- Enterobacter cloacae and Pseudomonas aeruginosa polymicrobial bloodstream infections traced to extrinsic contamination of a dextrose multidose vialThe Journal of Pediatrics, 1998
- Neonatal infections with Pseudomonas aeruginosa associated with a water-bath used to thaw fresh frozen plasmaJournal of Hospital Infection, 1998
- Multi-resistant Pseudomonas aeruginosa outbreak associated with contaminated tap water in a neurosurgery intensive care unitJournal of Hospital Infection, 1998
- Pseudomonas aeruginosa outbreak associated with a contaminated blood-gas analyser in a neonatal intensive care unitJournal of Hospital Infection, 1996