Arterial pulse wave analysis: An accurate means of determining cardiac output in children*
Authors:
- W Jeffrey DreyerWDW Jeffrey Dreyer
- Anthony C. ChangACAnthony C. Chang
- John P. BreinholtJBJohn P. Breinholt
- Ronald G. GrifkaRGRonald G. Grifka
- 1 November 2006
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 7 (6) , 532-535
Abstract
Cardiac output is a useful measure of myocardial performance. Standard methods of determining cardiac output are not without risk and can be problematic in children. Arterial pulse wave analysis (PulseCO), a novel, minimally invasive cardiac output determination technique, offers the advantage of continuous monitoring, convenience, and low risk. This technique has not been validated in children. The purpose of this study was to validate PulseCO as an accurate means of noninvasively determining real-time cardiac output in children. Prospective, single-center evaluation. Children's hospital. Any child with a structurally normal heart, undergoing hemodynamic evaluation in the cardiac catheterization laboratory, was included. A prograde right heart catheterization was performed, and cardiac output was determined using the thermodilution technique, via placement of a pulmonary arterial catheter. Thermodilution results were compared with continuous real-time cardiac output measurements obtained with the PulseCO system, and they were then analyzed by standard correlation techniques and Bland-Altman analysis. Twenty patients were evaluated with a median age of 10.5 yrs and a median weight of 25 kg. The mean thermodilution cardiac index was 3.3 +/- 0.9 L/min/m, whereas the mean PulseCO cardiac index was 3.1 +/- 0.9 L/min/m. Standard Pearson correlation tests revealed a correlation coefficient of .94 (p < .001). Bland-Altman analysis revealed excellent clinical agreement with a mean difference of 0.19 L/min/m and a precision of 0.28 L/min/m at 2 sd. Arterial pulse wave analysis by the PulseCO system provides a novel, minimally invasive method of determining real-time cardiac output in children.Keywords
This publication has 13 references indexed in Scilit:
- Early goal-directed therapy: An evidence-based reviewCritical Care Medicine, 2004
- Multiple organ dysfunction syndrome in children*Pediatric Critical Care Medicine, 2003
- Mortality and the nature of metabolic acidosis in children with shockIntensive Care Medicine, 2003
- Monitoring cardiac function in intensive careArchives of Disease in Childhood, 2003
- Pulseco: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgeryThe Annals of Thoracic Surgery, 2002
- Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac outputCurrent Opinion in Critical Care, 2002
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockNew England Journal of Medicine, 2001
- A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement TechniquesJournal of Clinical Monitoring and Computing, 1999
- Clinicians' abilities to estimate cardiac index in ventilated children and infantsArchives of Disease in Childhood, 1997
- Timing and predictors of death in pediatric patients with multiple organ system failureCritical Care Medicine, 1994