The impact of the number of sessions and stimulation parameters on repetitive transcranial magnetic stimulation efficacy for post-stroke upper extremity recovery: A systematic review and meta-analysis
- 13 April 2025
- journal article
- review article
- Published by SAGE Publications in Clinical Rehabilitation
Abstract
Objective: To identify the optimal number of sessions and parameters of repetitive transcranial magnetic stimulation frequency, stimulation intensity, number of pulses per session/treatment that promotes a greater effect on post-stroke upper extremity function. Data sources: MEDLINE (PubMed), Cumulative Index to Nursing and Allied Health Literature, Physiotherapy Evidence Database, Latin American and Caribbean Health Science Literature, Scientific Electronic Library Online, and Scopus up to November 2024. Review methods: We conducted a meta-analysis on randomized controlled trials of repetitive transcranial magnetic stimulation combined with other therapies for post-stroke upper extremity function, assessed risk-of-bias using the Physiotherapy Evidence Database scale, calculated standard mean differences (SMD) with 95% confidence intervals (CI), and determined parameter cutoff points using a receiver operating characteristic curve. Results: Thirty-five randomized clinical trials involving 897 patients were included. Compared to control groups, repetitive transcranial magnetic stimulation combined with other therapies improved upper extremity motor function with a higher effect size for: ≥ 15 sessions (SMD 0.72 95% CI, 0.37 to 1.08; p < 0.0001]), > 1 Hz frequencies (0.98 [95% CI, 0.48 to 1.48; p = 0001]), intensities of <100% of resting motor threshold (SMD 0.52 [95% CI, 0.29 to 0.75; p < 0.00001]), ≥ 1000 pulses per session (SMD 0.61 [95% CI, 0.40 to 0.82; p < 0.00001]), and ≥12,000 pulses per treatment (SMD 0.64 [95% CI, 0.36 to 0.93; p < 0.0001]). Conclusion: To enhance post-stroke upper extremity function, the optimal repetitive transcranial magnetic stimulation protocol involves at least 15 sessions, frequencies above 1 Hz, intensities below 100% of resting motor threshold, at least 1000 pulses per session, and 12,000 pulses per treatment.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This publication has 79 references indexed in Scilit:
- Does repetitive transcranial magnetic stimulation improve cognitive function in age‐related neurodegenerative diseases? A systematic review and meta‐analysisInternational Journal of Geriatric Psychiatry, 2023
- Mirror therapy in upper limb motor recovery and activities of daily living, and its neural correlates in stroke individuals: A systematic review and meta-analysisBrain Research Bulletin, 2021
- Efficacy of Low-Frequency Repetitive Transcranial Magnetic Stimulation in Ischemic Stroke: A Double-Blind Randomized Controlled TrialArchives of Rehabilitation Research and Clinical Translation, 2020
- Cochrane Handbook for Systematic Reviews of Interventions2019
- Analysing data and undertaking meta‐analyses2019
- Effect of combined low-frequency repetitive transcranial magnetic stimulation and virtual reality training on upper limb function in subacute stroke: a double-blind randomized controlled trailCurrent Medical Science, 2015
- Interventions for improving upper limb function after strokeCochrane Database of Systematic Reviews, 2014
- Efficacy of Coupling Repetitive Transcranial Magnetic Stimulation and Physical Therapy to Reduce Upper-Limb Spasticity in Patients With Stroke: A Randomized Controlled TrialArchives of Physical Medicine and Rehabilitation, 2014
- Electric field depth–focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designsBrain Stimulation, 2013
- Improving the antidepressant efficacy of transcranial magnetic stimulation: maximizing the number of stimulations and treatment location in treatment-resistant depressionDepression and Anxiety, 2011