Initial experience in Japan with HeartWare ventricular assist system
Authors:
- 25 January 2014
- journal article
- clinical trial
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (2) , 149-156
Abstract
We describe the first clinical experiences in Japan with the HeartWare ventricular assist device (HVAD: HeartWare Inc., Miami Lakes, FL, USA) in patients awaiting heart transplantation. Nine patients (6 males, 3 females; mean 33.5 ± 7.8 years; New York Heart Association class III or IV) received the HVAD as a bridge to transplantation between 2011 and 2012. Six had dilated cardiomyopathy, 2 secondary cardiomyopathy, and 1 dilated phase hypertrophic cardiomyopathy. All operations were uneventful, with a mean operation time of 269 ± 77 min and cardiopulmonary bypass time of 121 ± 40 min. One required a temporary right ventricular assist device and was weaned on postoperative day 20, while another required pump exchange due to foreign tissue in the inflow. Mean support duration was 245 ± 162 days (range: 50–535 days) and mean pump blood flow at 1 month postoperatively was 4.8 ± 0.8 l/min. There was no mortality after 30 days, though 1 patient died during support due to cerebral hemorrhage. Presently, the others are waiting for heart transplantation without problems, except 1 who suffered from an active infection. There was no pump mechanical failure in any case. The HeartWare pump enables quick implantation with acceptable morbidity and mortality. Our preliminary results indicate that this left ventricular assist device is safe for circulatory assistance for heart transplant candidates in Japan.Keywords
This publication has 17 references indexed in Scilit:
- Use of an Intrapericardial, Continuous-Flow, Centrifugal Pump in Patients Awaiting Heart TransplantationCirculation, 2012
- Initial Experience of Conversion of Toyobo Paracorporeal Left Ventricular Assist Device to DuraHeart Left Ventricular Assist DeviceCirculation Journal, 2012
- Acquired von Willebrand Syndrome in Patients With an Axial Flow Left Ventricular Assist DeviceCirculation: Heart Failure, 2010
- Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trialThe Journal of Heart and Lung Transplantation, 2010
- Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of TransplantationJACC, 2010
- Mechanical circulatory support devices (MCSD) in Japan: current status and future directionsJournal of Artificial Organs, 2005
- EVAHEART™: An implantable centrifugal blood pump for long-term circulatory supportThe Japanese Journal of Thoracic and Cardiovascular Surgery, 2002
- Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist SystemCirculation, 2002
- Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantationThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureThe New England journal of medicine, 2001